10.6084/m9.figshare.9986249.v1ABSTRACT Objective: Evaluate the physiological and autonomic nervous system responses of premature newborns to body position and noise in the neonatal intensive care unit. Methods: A quasi-experimental study. The autonomic nervous system of newborns was evaluated based on heart rate variability when the newborns were exposed to environmental noise and placed in different positions: supine without support, supine with manual restraint and prone. Results: Fifty premature newborns were evaluated (gestational age: 32.6 ± 2.3 weeks; weight: 1816 ± 493g; and Brazelton sleep/awake level: 3 to 4). A positive correlation was found between environmental noise and sympathetic activity (R = 0.27, p = 0.04). The mean environmental noise was 53 ± 14dB. The heart rate was higher in the supine position than in the manual restraint and prone positions (148.7 ± 21.6, 141.9 ± 16 and 144 ± 13, respectively) (p = 0.001). Sympathetic activity, represented by a low frequency index, was higher in the supine position (p
Keyword(s):
Autonomic nervous system; Heart rate/physiology; Infant, newborn; Intensive Care; Noise.