Loading...
Loading...
Contributors:
Dataset URI:
10.6084/m9.figshare.32090722.v1This dataset was collected to evaluate the acute effects of muscle activity biofeedback on power output during the bench press and squat exercises. Physiological, kinetic and kinematic data were collected from 24 healthy young adults, who performed the bench press and squat exercises at multiple relative loads across three sessions, under two auditory conditions: acoustic biofeedback (ABF) and generic gym music (GM). In the final session, participants were asked to rate their perceived enjoyment under each auditory condition.Experimental DesignEach participant performed three sessions of power testing under both ABF and GM stimuli at the Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa, using the Speediance® GYM Monster 2 Digital Weight Machine (Shanghai, China) to provide resistance. At the end of each session, participants completed the PACES-8 questionnaire, the Portuguese 8-item version of the Physical Activity Enjoyment Scale. Twenty-four participants were recruited, most from the Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa and two from another institution. The sample included 12 males and 12 females, with an age of 22.2 ± 2.2 years.Data CollectionTo collect physiological, kinematic, and force signals during the power tests, an 8-channel biosignalsplux wireless hub device with 16-bit resolution (PLUX Wireless Biosignals, Lisbon, Portugal) was used at a sampling rate of 1000 Hz.Physiological signals included muscle activity, acquired with two electromyography (EMG) sensors (PLUX Wireless Biosignals S.A., Portugal). Ag/AgCl adhesive electrodes were placed on the triceps brachii, at the midpoint between the posterior acromion and the olecranon, and on the vastus lateralis, at two-thirds of the line from the anterior superior iliac spine to the lateral border of the patella, on the dominant side. The EMG reference electrode was placed over the olecranon process.Heart activity was also monitored using an electrocardiography (ECG) sensor (PLUX Wireless Biosignals S.A., Portugal), with three Ag/AgCl electrodes positioned according to a placement previously established by the researchers to minimize movement interference in the signal. The positive electrode was placed below the sternum, close to the medial plane, and the negative electrode was placed below the left breast, close to the nipple. The ground electrode was positioned on the manubrium, in the upper portion of the sternum.Kinematic signals were measured using a triaxial accelerometer (ACC) (PLUX Wireless Biosignals S.A., Portugal), and force was measured using a load cell (PLUX Wireless Biosignals S.A., Portugal), both attached to the barbell of the weight machine. The ACC z-axis was aligned with the direction of movement.At the beginning and at the end of each session, resting-state signals were acquired for 2 minutes without the accelerometer and load cell sensors. These recordings correspond to the idx_initial_measures.txt and idx_final_measures.txt files, where idx stands for subject ID.Each exercise was recorded separately at each relative load. Recordings started shortly before the beginning of the first repetition and ended after the 2-minute rest period between sets of the same exercise.Data Structure and DescriptionThe main folder contains all subject folders and four files: one accelerometer calibration file (Acc_calib.txt), a subject characterization file (Sub_info.txt), the scores of the the Portuguese 8-item version of the Physical Activity Enjoyment Scale (PACES-8) (PACES8_scores.txt) and a file with the name of the files with missing values (files_with_missing_values.csv).The subject characterization file contains sex (1 = male, 2 = female), age (years), body mass (kg), body fat(\%), lean mass (kg), height (m), handgrip strength (kg), 1-repetition maximum (1-RM) for the bench press (kg), 1-RM for the squat (kg) and Physical Activity Level (Low, Moderate and High) for each participant ID.The files_with_missing_values.csv file indicates the names of the files that contain missing values (NaN), the total number of missing values in that file, the maximum number of consecutive missing values, and the total number of missing value blocks, considered as segments of data with at least two consecutive missing values.The data shared in this dataset is raw and has not been corrected, so users can decide how to handle missing samples.The data are divided into 24 folders, with one folder per participant. Within these folders, data are separated into session folders, which contain one folder per stimulus condition, ABF and GM, as well as the initial and final measurement files. In each stimulus folder, there are raw .txt files containing the recordings of each exercise at each relative load.A schema of the dataset organization is presented below:Dataset│├── IDx│ ││ ├── Session_1│ │ ││ │ ├── GM│ │ │ ├── idx_relativeload_mp_squat_gm.txt│ │ │ ├── idx_relativeload_mp_bp_gm.txt│ │ │ └── ...│ │ ││ │ ├── ABF│ │ │ └── ...│ │ ││ │ ├── idx_initial_measures.txt│ │ └── idx_final_measures.txt│ ││ ├── Session_2│ │ └── same structure│ ││ └── Session_3│ └── same structure│├── IDy│ └── ...│├── Sub_info.txt│├── files_with_missing_values.csv│├── PACES8_scores.txt│└── Acc_calib.txtThe file names follow the structure idx_relativeload_mp_exercise_stimulus, where idx represents the particpant ID, relativeload the percentage of the 1-RM at which the exercise was being performed, mp stands por muscle power, the exercise can be bp - bench press or squat - squat and stimulus is either abf - acoutic biofeedback or gm - gym music.Initial and Final Measurement Files StructurenSeq - sequence numberEMGA - EMG data from the sensor placed over the triceps brachii (arm)EMGL - EMG data from the sensor placed over the vastus lateralis (leg)ECG - ECG dataSession Files StructureFor the exercise recordings, the columns are:nSeq - sequence numberLOADCELL - data from the load cell sensorACCx - data from the x-axis of the accelerometer sensorACCy - data from the y-axis of the accelerometer sensorACCz - data from the z-axis of the accelerometer sensorEMGA - EMG data from the sensor placed over the triceps brachii (arm)EMGL - EMG data from the sensor placed over the vastus lateralis (leg)ECG - ECG dataData Usage and ProcessingAll sensor data are provided in ADC values and not in physical units. To convert these values into physical units, please check the datasheet available for each sensor:EMGECGACCFor the accelerometer, a calibration procedure was followed according to the ACC datasheet. The calibration values can be extracted from the Acc_calib.txt file.For the load cell, the following equation was used after sensor calibration using known weights:Force (kg) = −0.0029x + 94.2825An example of data usage, including a code snippet for data extraction, is presented below:# Loading bench press data from subject ID3, Session 2, at 40% of 1-repetition maximum,# under the ABF stimulus.file_path = "Acoustic BioPower\\ID3\\Session_2\\ABF\\id3_40_mp_bp_abf.txt"with open(file_path, "r") as f: lines = f.readlines()# Columnsheader_line = lines[0].strip("\t")column_labels = header_line.split()# Datadata_lines = [line.strip().split("\t") for line in lines[1:]]df = pd.DataFrame(data_lines, columns=column_labels)for c in list(df.columns): df[c] = pd.to_numeric(df[c], errors="coerce")This dataset can be freely used for academic purposes. Users should cite the associated article and the dataset DOI when reusing the data.EthicsThe study protocol was approved by the Ethics Committee of the NOVA School of Science and Technology, reference CE_FCT_021-2025. Informed consent was obtained from all subjects involved in the study.
Keyword(s):
Accelerometer; Acoustic Biofeedback; Biomedical instrumentation; Biosignals; Computational physiology.
MeSH Term(s):
Grants and Funding:
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)