10.25403/UPresearchdata.32947238.v2This dataset contains processed PET/CT and SPECT/CT imaging data together with the derived quantitative measurements from a series of phantom-based and clinical studies characterising image quality and optimising reconstruction parameters on new-generation digital nuclear medicine systems. The work spans four related investigations:Characterisation and optimisation of a digital BGO PET/CT system (GE Omni Legend 32) with ⁶⁸Ga. Data were acquired under routine clinical conditions using a uniform cylindrical (Jaszczak) phantom, a flangeless Esser PET phantom, and a NEMA IEC body phantom, with dose-calibrator and gamma-counter cross-calibration. Images were reconstructed with Q.Clear (β = 100–800) and SharpIR (2–10 iterations, 12 subsets fixed) and evaluated using standardised uptake value (SUV), contrast recovery coefficient (CRC), recovery coefficient (RC), contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and coefficient of variation (CoV). Recommended reconstruction settings for clinical ⁶⁸Ga tracers (PSMA, DOTATATE, FAPI) are included.Phantom-based comparison of two digital PET/CT systems with different axial fields of view (Siemens Biograph Vision 450 vs Vision 600). A flangeless Esser PET phantom with cold-rod, cold-sphere, and refillable hot-cylinder inserts was imaged and reconstructed with TOF-OSEM (3 iterations, 5 subsets, with PSF and TOF modelling). Outputs include CRC, CNR, and SNR for hot cylinders and cold spheres, line profiles across cylindrical inserts; and a FlowMotion scan-speed comparison.Clinical evaluation of Q.Clear versus SharpIR for ⁶⁸Ga PET/CT on a digital BGO scanner. Patient ⁶⁸Ga-PSMA and ⁶⁸Ga-FAPI studies were analysed for SUVmean/SUVmax, liver background noise, signal-to-background ratio (SBR), SNR and lesion conspicuity, with Bland–Altman agreement analysis, lesion-size correlations, and recovery-coefficient-based partial-volume-effect (PVE) correction.Multi-metric optimisation of reconstruction parameters for quantitative ⁹⁹ᵐTc CZT-SPECT/CT. OSEM, Q.Clear, Q.Clear RDP and Q.Clear MRP reconstructions were evaluated across 5–20 iterations and 5–20 subsets using image calibration factor (ICF), CRC, background variability, recovery coefficient, and lung error, including an exponential PVE-correction fit derived from NEMA IEC phantom spheres.The dataset comprises processed transaxial and maximum-intensity-projection images, calibration curves, line profiles, and the corresponding tabulated quantitative metrics and summary plots. It supports benchmarking and harmonisation of PET/CT and SPECT/CT reconstruction algorithms, development and validation of partial-volume-correction methods, cross-scanner comparison, and protocol optimisation for ⁶⁸Ga and ⁹⁹ᵐTc imaging, as well as teaching in quantitative nuclear medicine imaging.This study aimed to evaluate and optimise the quantitative accuracy and image quality of modern PET/CT and SPECT/CT systems through systematic calibration, reconstruction optimisation, hardware performance evaluation, and clinical validation. The work combined controlled phantom experiments with retrospective anonymised clinical datasets to investigate radionuclide-specific imaging performance, with particular emphasis on imaging using Gallium-68 PET/CT and Technetium-99m SPECT/CT.
Keyword(s):
Image quality; Other health sciences not elsewhere classified; Positron emission tomography (PET)/computed tomography (CT) imaging; Quantitative imaging; Reconstruction optimisation.
Grants and Funding:
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)