Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.21493204Supporting data for the article "Conductometric Process Analytical Technology for Real-Time Endpoint Control of Graphene Oxide Dialysis Purification" (Mr. S.P. Popov, Mr. V.A. Manuilenko, Mr. V.V. Koshlan, Prof. Dr. M.A. Proskurnin, Dr. I.V. Mikheev; Lomonosov Moscow State University). Submitted to: Analytica Chimica Acta (Fri Jul 31, 2026). The deposit contains raw and processed data, analysis code, and a consolidated long-format dataset needed to reproduce the figures and tables of the article and its Supporting Information. It covers eight dialysis purification experiments monitored by in-line conductometry (10-second logging), with hourly conductivity increments (delta-kappa), the Ki / Ki-tilde stopping criterion, ICP-OES metal concentrations (Mn, Ti) for validation, and FTIR spectra before and after H2O2 treatment. Funded by the Russian Science Foundation (project No. 24-73-10012). Version 2 (15 September 2026). Data set updated for the revised manuscript (resubmitted to Analytica Chimica Acta, ACA-26-3567) after the first round of peer review. Supporting data for the article "Conductometric Process Analytical Technology for Real-Time Endpoint Control of Graphene Oxide Dialysis Purification" (Mr. Sergey P. Popov, Mr. Vladislav A. Manuilenko, Mr. Victor V. Koshlan, Dr. Konstantin I. Maslakov, Dr. Evgeniy G. Evtushenko, Dr. Vita N. Nikitina, Mrs. Alena R. Karastsialiova, Prof. Dr. Mikhail A. Proskurnin, Dr. Ivan V. Mikheev; Lomonosov Moscow State University). Resubmitted to: Analytica Chimica Acta (Tue Sep 15, 2026).New in this version: Conductivity logs (10-s step) of the new dialysis runs: a conventional dialysis run against water with manual exchange of the medium (run D10, with the ATR-FTIR spectra of the purified GO), and the blank run (reactor without GO) and the KCl tracer run of the reactor (folders blank-run and tracer-run). High-resolution XPS spectra (survey and C 1s, O 1s, Mn 2p, S 2p, N 1s regions) of unpurified GO and of GO purified by runs D6 and D8. Raman spectra (25 spots per sample) of the same three samples. Processing scripts and tables: blank_tracer_analysis.py (SI Section 17), exchange_fraction_sweep.py and fig_S24.py with the csv tables of the exchange-fraction sweep (folder exchange-fraction-sweep, SI Section 19), ti_prediction_error.py (SI Section 20).
Keyword(s):
conductometry; dialysis; graphene oxide; ICP-OES; nanomaterials.
MeSH Term(s):
Grants and Funding:
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)