Loading...
Loading...
Contributors:
Dataset URI:
10.11583/DTU.32415357.v2This dataset supports the findings reported in:Veigel, C., Relaño-Iborra H., Oxenham A.J., Dau, T.; A model-based analysis of modulation masking effects on vocoded speech intelligibility. J. Acoust. Soc. Am. September 2026; 160 (3): 2090–2104. https://doi.org/10.1121/10.0046394The README gives a detailed description of the files, structure and variables of the dataset. The behavioral data replicated and extended the findings from Oxenham and Kreft (2014).The dataset contains behavioral data of 14 native English speaking participants with normal-hearing. The data collected was:Population data: age, gender, English dialectPure-tone audiogramsPercent correctly understood words for half-AzBio sentence lists (Spahr et al, 2012) in noise, both unprocessed and tone-vocoded.Furthermore the dataset contains all masker stimuli, the vocoder MATLAB functions (same as in Oxenham and Kreft, 2014) as well as the model predictions of the data, generated with the speech-based envelope power spectrum model with a correlation back-end (sEPSMcorr, Relaño-Iborra et al, 2016, modified in Veigel et al, 2026). The model including its versions are available here.The dataset is licensed under Creative Commons Attribution 4.0 (CC BY 4.0)Files Descriptionspopulation_data_audiograms.csv: age, gender, dialect and audiograms of the test subjects.subject: subject number.only subjects after data selection are included (see *data_collection_and_selection.pdf*)gender: gender that the subject identifed as (no options were given)m = masculinf = femininage: age of the subjects at the moment the data was collected (in years)dialect: self-reported English dialect of the subjectR_0.25kHz: pure tone threshold at 0.25 kHz in dB HL for the right earR_0.5kHz: pure tone threshold at 0.5 kHz in dB HL for the right earR_1kHz: pure tone threshold at 1 kHz in dB HL for the right earR_2kHz: pure tone threshold at 2 kHz in dB HL for the right earR_4kHz: pure tone threshold at 4 kHz in dB HL for the right earR_8kHz: pure tone threshold at 8 kHz in dB HL for the right earL_0.25kHz: pure tone threshold at 0.25 kHz in dB HL for the left earL_0.5kHz: pure tone threshold at 0.5 kHz in dB HL for the left earL_1kHz: pure tone threshold at 1 kHz in dB HL for the left earL_2kHz: pure tone threshold at 2 kHz in dB HL for the left earL_4kHz: pure tone threshold at 4 kHz in dB HL for the left earL_8kHz: pure tone threshold at 8 kHz in dB HL for the left earPTA4(dB HL): pure tone average threshold of the frequencies 0.5,1,2,4 kHz of left and right earBehavioral_Data_Pcorrect_avg_per_list.csv: Speech intelligibility was measured as percent correctly understood words in different processing and masker conditions. Percent correct scores were averaged per half-AzBio lists (10 sentences).subject: subject number.Includes the subjects after data selection (see *data_collection_and_selection.pdf*)condition: processing condition.unpro = unprocessed,bp = bandpass-filtered (cutoffs of the vocoder),voc1 = 16-channel tone-vocoded without current spread, orvoc2 = 16-channel tone-vocoded with simulated current spreadmasker: masker type.SSN = speech shaped noise,SSNbp = bandpass-filtered speech shaped noise (cutoffs of the vocoder, measured only in unpro condition),PT = pure-tone complex,MT = modulated pure-tone complex, orPT+2LF = pure-tone complex with two additional low frequencies (measured only in unpro condition)Pcorrect: averaged word correct percentage (in %) for the measured list (=10 sentences)A detailed description of the masker types and the processing conditions are available in the article Veigel et al (2026).data_collection_and_selection.pdf: explanation of which data was included in the final, published dataset, as some of the data had to be excluded due to technical and time issues.masker_files.zip: wav-files of the 5 masker types used in Veigel et al (2026).The files are 20 s long, sampled with a sampling frequency of 22050 Hz. Assume that all maskers have an rms-level of -20 dB, eventhough the maskers SSNbp, PT and MT actually have lower rms-levels, as they were created to fit the SSN energy per vocoder channel. Energy below and above the vocoder passband are not represented in those maskers - thus the maskers have same rms per vocoder channel, but the overall rms is different and should not be normalized in order to replicate the study. This leads to relative overall SNR differences across maskers in the unprocessed condition, but not in the other conditions (for more information see Veigel et al, 2026).vocoder_code.zip: matlab functions to create the same vocoded signals as in this study. Vocoder implementations are the same as used in Oxenham and Kreft (2014). Published with permission.demod_vocoder.m: tone-excited envelope vocoder. Takes the signal to vocode (x), the vocoder channel center frequencies (channel_cfs, in this study: [333 455 540 642 762 906 1076 1278 1518 1803 2142 2544 3022 3590 4264 6665] Hz), the vocoder lowpass-filter cutoff (env_lpco, here: 50 Hz) and the sampling frequency (fs) as input and returns the vocoded singal (x_final_output).demod_vocoder_spread.m: tone-excited envelope vocoder that simulates current spread across vocoder channels. Takes x, channel_cfs, env_lpco and fs (same as in no-spread vocoder), as well as the the amount of attenuation of the spectral smearing across vocoder channels in dB/oct (spread, in this study: 8) as input and returns the vocoded singal (x_final_output).bandpass_filter.m: bandpass-filter design. Takes sampling frequency fs and filter order as inputs and returns filter coefficients a and bfolder functions: help functions for the vocoder implementationsPredicted_Pcorrect_avg_over_100sent.csv: sEPSMcorr (Relaño-Iborra et al, 2016, modified in Veigel et al, 2026) predictions. Find descriptions of the maskers types and processing conditions above and in Veigel et al (2026)condition: processing condition. unpro, bp, voc1 or voc2masker: masker type. SSN, PT or MTpred-Pcorrect: predictions of sEPSMcorr3, word correct percentage (in %), averaged across 100 sentencesEthical StatementAll participants received financial compensation for their time and provided written informed consent. The study was approved by the Science-Ethics Committee for the Capital Region of Denmark (reference: H-16036391).ReferencesSpahr, A. J., Dorman, M. F., Litvak, L. M., Van Wie, S., Gifford, R. H., Loizou, P. C., Loiselle, L. M., Oakes, T., Cook,S.: Development and Validation of the AzBio Sentence Lists. Ear and Hearing 33(1):p 112-117, January 2012. |DOI: 10.1097/AUD.0b013e31822c2549Relaño-Iborra, H., May, T., Zaar, J., Scheidiger, C., Dau, T.: Predicting speech intelligibility based on a correlation metric in the envelope power spectrum domain. J. Acoust. Soc. Am. 1 October 2016; 140 (4): 2670–2679.https://doi.org/10.1121/1.4964505Steinmetzger, K., Zaar, J., Relaño-Iborra, H., Rosen, S., Dau, T.: Predicting the effects of periodicity on theintelligibility of masked speech: An evaluation of different modelling approaches and their limitations. J.Acoust. Soc. Am. 1 October 2019; 146 (4): 2562–2576. https://doi.org/10.1121/1.5129050Oxenham A. J., Kreft H.A.: Speech Perception in Tones and Noise via Cochlear Implants Reveals Influence of Spectral Resolution on Temporal Processing. Trends in Hearing. 2014;18. doi:10.1177/2331216514553783Citation and linksCite this dataset:Veigel, C., Relaño-Iborra, H., Oxenham, A., Dau, T.: Dataset for "A model-based analysis of modulation masking effects on vocoded speech intelligibility". Technical University of Denmark. Dataset | DOI: https://doi.org/10.11583/DTU.32415357Corresponding article:Veigel, C., Relaño-Iborra H., Oxenham A.J., Dau, T.; A model-based analysis of modulation masking effects on vocoded speech intelligibility. J. Acoust. Soc. Am. September 2026; 160 (3): 2090–2104. https://doi.org/10.1121/10.0046394Corresponding preprint:Veigel, C., Relaño-Iborra, H., Oxenham, A., Dau, T.: A model-based analysis of modulation masking effects on vocoded speech intelligibility. PsyArXiv Preprint. March 27, 2026 | DOI:https://doi.org/10.31234/osf.io/3h9pv_v1Acknowledgments and fundingThis work has received funding by the Center for Applied Hearing Research (CAHR) and the William Demant Foundation (Grant Number 23-4855). Andrew J. Oxenham's contributions were supported by NIH grant R01 DC023255.
Keyword(s):
Hearing research; Modelling and simulation; modulation masking; Sensory processes, perception and performance; Speech intelligibility modelling.
MeSH Term(s):
Grants and Funding:
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)