Loading...
Loading...
Contributors:
Dataset URI:
doi:10.7910/DVN/PH4HB4Replication data for the paper Balance of Plant for a Compact Spherical-Tokamak Breeder: Heat Rejection, Cryoplant Load-Balancing, and Vacuum Scheduling for the 16.84 T Cold Mass (Kronos Fusion Energy 2026 Publication Series, paper 2.102), published at doi:10.5281/zenodo.22645901.Abstract of the paper. Between a fusion core and the grid sits the balance of plant (BOP), and beneath the whole machine sit the cryogenic and vacuum services that keep the cold mass superconducting and the chamber evacuated. We formalise the BOP of the Kronos Hyperion breeder as a coupled thermal–fluid–cryogenic–vacuum system and reduce it to a set of governing equations, a numerical formulation, and a demonstrated design envelope. At the ratified design point (Q=3.076, P_ fus=85.04, I_p=9.66, δ=-0.30, B_0=8, κ=2.0, =1.20, aspect ratio A=2.5) the blanket dissipates a thermal power P_ th=M_n P_n + P_ chg=95.2 built from a neutron power P_n=67.79 (energy multiplication M_n=1.15) and a charged-particle power P_ chg=17.25; removing it with helium at a temperature rise T=200 requires a mass flow m = P_ th/(c_p T)=91.7, a volumetric flow of ≈14.8 at the inlet loop condition (8, 350). The decisive BOP result is passive safety: after shutdown the decay heat falls as P_d(t) t^-0.203 from ≈0.95 at 1 to ≈95 at one day, and a Stefan–Boltzmann balance over the compact plasma-facing area (≈36, emissivity 0.5) rejects those levels at equilibrium wall temperatures of ≈711 and ≈290 respectively — below steel-damage territory, with no forced cooling required for survival; a lumped-capacitance transient shows the realised peak lies far below the quasi-static bound.What this dataset containsdata/key_values.csv and data/anchors.json: the frozen design-point values quoted in the paper (symbol, value, unit, provenance), in machine-readable form.data/verification.csv: the validator gates the paper cites, each with its verdict and a link to a live recompute page.figures/: the figures from the paper, as vector PDF, with an inventory.balance-of-plant-for-a-compact-spherical-tokamak-breede.data-methods.pdf: methods, the computational codes used, and the full value table.data/data_dictionary.md: column definitions.Every value is a frozen design-point number that is independently re-run and recorded in the Kronos Physics De-Risking Register (doi:10.5281/zenodo.22645689). The paper itself is not duplicated here; read it at the DOI above.
Keyword(s):
balance of plant; cryogenics; direct energy conversion; heat rejection; load-balancing.
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)