Loading...
Loading...
Contributors:
Dataset URI:
doi:10.7910/DVN/SMUDM2Replication data for the paper Neutron Streaming, Duct and Port Penetrations, and Occupational Dose Around a 14 MeV Compact Spherical-Tokamak Breeder (Kronos Fusion Energy 2026 Publication Series, paper 2.28), published at doi:10.5281/zenodo.22645842.Abstract of the paper. Every penetration through a breeder's shield is a leak in the neutron account and a source of occupational dose: the ducts that admit heating beams, diagnostics and direct-conversion hardware also let 14 neutrons stream past the blanket, activating the structure the maintainer must later approach. We give a closed, CAD-faithful treatment of that problem for the Hyperion compact spherical-tokamak breeder (P_ fus=85.04, Q=3.076, I_p=9.66, δ=-0.30, B_0=8, κ=2.0, =1.20, A=2.5). We first derive the governing linear transport equation and reduce it, for a penetration, to an analytic line-of-sight-plus-wall-albedo streaming model whose a^2/L^2 scaling and dog-leg suppression we then confront with three-dimensional Monte-Carlo transport. A 14 source of S_n=3.009e19 carrying 67.8 drives an OpenMC/ENDF-B-VIII.0 transport (1.2×10^8 histories) that closes the balance with a global leakage fraction of 0.121, a first-wall fast flux of 7.0e14 n cm^-2 s^-1, and 74.6 of nuclear heating; the net tritium breeding ratio runs from 1.014±0.004 on CAD-faithful DAGMC geometry to ≈1.15–1.20 in the realistic three-dimensional arbiter, and with real ports and penetrations settles at 1.12 (single-null) / 1.07 (double-null) — above the 1.05 design floor.What this dataset containsdata/key_values.csv and data/anchors.json: the frozen design-point values quoted in the paper (symbol, value, unit, provenance), in machine-readable form.data/verification.csv: the validator gates the paper cites, each with its verdict and a link to a live recompute page.figures/: the figures from the paper, as vector PDF, with an inventory.neutron-streaming-duct-and-port-penetrations-and-occupa.data-methods.pdf: methods, the computational codes used, and the full value table.data/data_dictionary.md: column definitions.Every value is a frozen design-point number that is independently re-run and recorded in the Kronos Physics De-Risking Register (doi:10.5281/zenodo.22645689). The paper itself is not duplicated here; read it at the DOI above.
Keyword(s):
DAGMC; duct penetration; neutron streaming; occupational dose; OpenMC.
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)