Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23084573MetalLipoDB contains 5158 experimentally measured octanol–water lipophilicity values (logP/logD) of 4714 unique complexes of 23 metals (Ru, Pt, Ir, Cu, Au, Fe, Tc, Rh, Re, Co, Os, Ag, Pd, Ni, Ga, Zn, Mn, V, Ti, In, Gd, Hg and Cd) reported in 1192 literature papers from 1997 to 2026. All values were obtained by the shake-flask method. The 28 columns of this dataset are explained as follows: record_id — stable identifier of the measurement (MLDB-000001, MLDB-000002, etc.) metal — the element(s) representing the metal centre(s) of the complex multinuclear — YES for complexes with more than one metal centre ccdc — CCDC reference code of the crystal structure (if available) smiles_complex — SMILES representation of the complex with dative metal-ligand bonds smiles_ligands — SMILES representation of ligands coordinated to the metal ion (for mononuclear complexes) counterion — SMILES representation of the counterion(s) (if the complex molecule is charged) complex_charge — total charge of the isolated complex molecule abbreviation_in_the_article — the original abbreviation depicting the complex in the article value — value of logP/logD presented as a number value_relation — relation of the reported value (=, <, > or ~) std — standard deviation of logP/logD originally presented in the article value_raw — value of logP/logD originally presented in the article type_authors — type of the value as named by the authors (logP or logD) method — experimental method of determination (shake-flask) detection — method of concentration determination (UV-Vis, ICP-MS, gamma counter, etc.) aqueous_phase — aqueous phase as described in the article (water, PBS, 0.9% NaCl, etc.) medium_class — class of the aqueous phase (water, salt / saline, buffer, buffer + salt, acid) pH — pH of the aqueous phase temperature_C — temperature of the measurement (°C) buffer_class — type of buffer in the aqueous phase (phosphate, Tris, HEPES, etc.) buffer_conc_mM — concentration of the buffer (mM) halide_type — halide anion present in the aqueous phase (Cl, Br, I) halide_conc_mM — concentration of the halide anion (mM) cosolvent — co-solvent and its fraction (if used) method_description — description of the experimental procedure quoted from the article doi — DOI of a data source for given values year — year of a data source for given values Notes: - Empty cells denote values not reported in the article; "absent" denotes a confirmed absence (e.g., no buffer or no halide in the aqueous phase). When reading with pandas, use keep_default_na=False, na_values=[""]. - type_authors reflects the authors' wording. Many values called logP were measured in buffers or for charged complexes; the conditions needed to distinguish logP from logD are given in pH, buffer_class, medium_class and complex_charge. - For radiometric tracer measurements (mostly 99mTc) of charged complexes, the counterion is empty because no stoichiometric counterion exists. - Where the aqueous phase is reported only as PBS without its composition, halide_conc_mM is taken from the standard recipe (140 mM chloride).
Keyword(s):
dataset; Lipophilicity; logD; logP; metal complexes.
MeSH Term(s):
Grants and Funding:
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)