Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23099489OverviewThis dataset contains raw time-series measurements collected by the Wireless Sensor Network (WSN) deployed in the Town Hall of Fornes (Granada, Spain). The building also houses the municipal theatre. The data cover indoor environmental conditions (air temperature, relative humidity, illuminance) and the electrical consumption of HVAC units (active power, current and cumulative active energy). The dataset was generated within Demo 5 "Grid-supporting Rural Renewable Energy Community" of the Horizon Europe project WeForming, led by Grupo Cuerva. A companion dataset with the same structure covers the Public Nursery of Fornes. ContextFornes is a rural village of about 555 inhabitants within the distribution network operated by Grupo Cuerva (local DSO and retailer) and part of Cuerva's Living Lab. The village hosts a Renewable Energy Community (REC) composed of 25 households and six public buildings, supplied by a shared 58 kW photovoltaic installation located on the roof of the Town Hall, of which 38.5 kW are allocated to the public buildings. The Town Hall is therefore both the PV host building and one of the main public consumers of the REC. Within the WSN, the HVAC units can be monitored and controlled (ON/OFF and setpoint), so that their operation can be adapted to occupancy, indoor conditions, PV availability and grid needs. The data feed the Day-Ahead energy optimisation model of the demo, which minimises electricity costs for the public buildings while keeping indoor temperature within comfort ranges. Monitoring systemThe WSN is based on the Z-Wave protocol (868.42 MHz, EU band; AES-128 encryption) in a mesh topology, in which mains-powered nodes (smart switches, meters) relay messages from battery-powered nodes (multisensors). The master controller and data aggregator of the network, a Raspberry Pi 4 with a Z-Wave USB gateway, is installed in the Town Hall. Data are stored in Cuerva's common database for the Fornes energy community and made available to the project platforms. The devices installed in the building are: Aeotec Multisensor 7 (temperature, relative humidity, illuminance, plus motion/presence, UV and tamper) MCO Home IR Thermostat IR2900 (ambient temperature and infrared control of the HVAC units) Aeotec Smart Switch 7 (ON/OFF switching and metering of HVAC units: power, current, energy) QUBINO Z-Wave smart meter (DIN-rail) Dataset structureOne CSV file is provided per device and measured variable, named <DeviceID>_<Variable>.csv. The device ID prefix identifies the device type: MS = multisensor, AC = HVAC thermostat, SS = smart switch. Each file has two columns: time: timestamp of the reading (YYYY-MM-DD HH:MM:SS), in local time (Europe/Madrid: CET, UTC+1, in winter; CEST, UTC+2, in summer). No time-zone offset is included in the timestamps. value: measured value Variable (file suffix) Unit Device type Typical reporting interval Sensor_temperature °C Multisensor / thermostat ~10 min (event-based) Sensor_relative_humidity % RH Multisensor ~20 min (event-based) Sensor_luminance lux Multisensor ~5 min (event-based) Electric_meter_watts W (active power) Smart switch (HVAC) ~5 min Electric_meter_amps A (current) Smart switch (HVAC) ~5 min Electric_meter_kWh kWh (cumulative active energy) Smart switch (HVAC) ~5 min The "Electric_meter" files of smart switches correspond to the metering function of each switch, i.e. the consumption of the individual HVAC unit connected to it, not of the whole building. The file device_metadata.csv maps each device ID to its room or zone (including the theatre), device model, variable and unit. Temporal coverage17 January 2025 – 31 December 2025 (some files extend to the early hours of 1 January 2026). Readings are event-driven (sent on value change or periodic report), so time steps are irregular and differ between variables and devices. Users who need regular time series should resample (e.g. to 15 min or 1 h). Data processing and qualityData are provided as raw records exported from the database, without gap filling, outlier removal or resampling, so that users can apply their own cleaning procedures. Known issues include: Data gaps due to communication losses or battery-powered devices going offline (e.g. gaps of up to ~16 days in February 2025 for smart switch metering and up to ~5 days for some thermostats). Until late May 2025, smart switch metering values were reported roughly once per day; from June 2025 onwards the reporting interval is ~5 minutes. Occasional physically implausible values (e.g. temperatures above 100 °C, an illuminance reading of 536,870,944 lux, isolated zero readings), attributable to transmission or device errors. Isolated non-monotonic values in cumulative energy (kWh) series. A small number of duplicated timestamps. Because timestamps are in local time without offset, the end of daylight saving time (26 October 2025) produces repeated timestamps in the early morning (between 02:00 and 04:00), and records in that interval are not in chronological order in the files. Users should convert timestamps to UTC with care or exclude this interval for high-resolution analyses. Potential usesAnalysis of indoor thermal comfort and HVAC usage in a multi-use public building (offices and theatre) in a Mediterranean continental climate; development and validation of load-forecasting, occupancy-based control and demand-side management (DSM) algorithms; flexibility assessment of HVAC loads; building energy model calibration; benchmarking of low-cost IoT monitoring systems; Smart Readiness Indicator (SRI) and energy community studies. Keywords: wireless sensor network; Z-Wave; smart buildings; public buildings; town hall; HVAC; indoor environmental quality; thermal comfort; energy consumption; demand-side management; flexibility; renewable energy community; rural energy community; IoT; time series; WeForming; Fornes; Spain
Keyword(s):
MeSH Term(s):
Grants and Funding:
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)