Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23024117This dataset contains experimental Mössbauer spectra, spectral fitting models and results, and sample mass and diameter measurements supporting the associated study. Sample measurements (Mass and Diameter.xlsx): A spreadsheet containing sample mass and diameter measurements, identified by sample name. Spectra were analyzed using the March 2025 version of SyncMoss (Yaroslavtsev, 2023). Three fitting approaches, designated Fit 1, Fit 2, and Fit 3, were applied to each spectrum. Files are organized by sample identifier and fitting approach. For example, KO16t03@6mm.txt contains the experimental spectrum, and files beginning with KO16t03_Fit1 contain the corresponding Fit 1 outputs. The following file types are included: Experimental spectra (*@6mm.txt): Two-column, tab-separated text files containing Doppler velocity (mm/s) and measured transmission counts, without a header. The suffix @6mm denotes a nominal velocity range of ±6 mm/s; the exact velocities are provided in the first column. Saved fitting models (*_model.mdl): SyncMoss model files preserving the model components, parameter values, and fitting constraints for inspection and further fitting. Fitting parameters (*_param.txt): Tab-separated summaries of baseline parameters, component intensities, spectral parameters, uncertainties where available, and the χ² statistic reported by SyncMoss. Column headings retain the software’s notation. Numerical fitting outputs (*_graf.txt): Tab-separated data containing velocity, measured counts, the complete fitted model, residuals, the baseline, and individual model-component curves. Residuals are defined as measured counts minus fitted counts. Spectrum plots (*.svg): Vector-format plots of the fitted spectra. Combined fitting summaries (*_combo.png): Images displaying the experimental spectrum, fitted model components, residuals, and fitting-parameter table. Each experimental spectrum is shared by its three fitting approaches, with a separate set of model files and outputs provided for each approach. The numerical exports allow readers to inspect and replot the results, while the saved models document the fitting configurations. Some fitting outputs retain original measurement filenames; for example, km0616t03.txt is the original filename for sample KOt03. Entries marked nan indicate that a numerical value or uncertainty was not reported and should not be interpreted as zero. Exported component intensities are not necessarily equivalent to corrected Fe³⁺/ΣFe values; conversion requires the appropriate component assignments and any recoilless-fraction correction applied in the study.
Keyword(s):
MeSH Term(s):
Grants and Funding:
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)