10.5281/zenodo.23207188This dataset contains representative SAXS, WAXS, and Bonse–Hart USAXS measurements acquired at beamline I22 of Diamond Light Source for use as a MoDaCor processing example. The SAXS/WAXS subset contains four operando measurements of a 50 µm 3YSZ–PEGDA specimen, an empty-furnace background measurement, a glassy-carbon absolute-intensity calibration measurement and reference curve, detector calibrations, masks, and the associated NeXus/HDF5 sidecar files. The USAXS subset contains one empty-furnace acquisition and three sample acquisitions at 1153.2, 1162.7, and 1175.4 °C. Each acquisition comprises low- and high-gain rocking scans, each paired with a preceding diode dark measurement. The scans record front and rear diodes, the I0 monitor, analyser yaw, and count time. The NeXus masters use relative external links to their associated HDF5 sidecars. Extract the archive as a unit and preserve its directory structure. The payload is intended for the I22 notebooks and processing pipelines in the MoDaCor-examples repository.