10.5281/zenodo.23205553This dataset contains experimental and analytical data on the effect of different reflector materials on the outdoor thermal performance of helical-absorber parabolic trough collectors. It includes measurements of solar irradiance, ambient and absorber temperatures, heat-transfer fluid temperatures, reflector temperature, and thermal response under varying operating conditions. The dataset supports the assessment and comparison of reflector materials in terms of temperature distribution, heat gain, and overall thermal performance of the parabolic trough collector.