Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23246616Example hard X-ray ptychographic dataset recorded at SoftiMAX beamline [1] at the MAX IV Laboratory [2]. The dataset was recorded on a Siemens star sample. The data is kept in the folder and file structure typical to the lab and beamline. The upload contains the raw data, the script used to reconstruct the raw, the final reconstruction results and a jupyter notebook loading the reconstructions to create a figure of the reconstructed objects. Data was recorded at a photon energy of 853 eV. A Fresnel zone plane (300 µm diameter, 25nm outermost zone width) was used to focus the probing X-ray beam about 5.165mm downstrem of the zone plate. A 90µm central stop was used to block the direct beam. The sample was positioned about 20µm downsteam of the focus to create a beam footprint of about 1µm on the sample. The sample was scanned in a Fermat-spiral scanning pattern [3] over a scan region of 8µm x 8µm with an average step size of 0.14µm. At each scan position a diffraction pattern was recorded with an LGAD Eiger prototype detector (DECTRIS, Switzerland) [4] and an exposure time of 10ms per scan point. The detector was positioned 70mm downstream of the sample. Reconstructions were performed using the ptypy-framework [5] using 2000 iterations of the difference-map (DM) algorithm [6], followed by 4000 iterations of the maximum likelihood (ML) algorithm [7] implemented for GPUs using cupy [8]. Four probe [9] modes were used for the reconstruction in all algorithms. We acknowledge the MAX IV Laboratory for beamtime on the SoftiMAX beamline under proposal 20251284. Research conducted at MAX IV, a Swedish national user facility, is supported by Vetenskapsrådet (Swedish Research Council, VR) under contract 2018-07152, Vinnova (Swedish Governmental Agency for Innovation Systems) under contract 2018-04969 and Formas under contract 2019-02496. References: [1] Jörg Schwenke et al. - Microscopy and Microanalysis, Volume 24, Issue S2, 1 August 2018, Pages 232–233, https://doi.org/10.1017/S143192761801351X[2] Aymeric Robert et al., "MAX IV Laboratory". Eur. Phys. J. Plus 138, 495 (2023). https://doi.org/10.1140/epjp/s13360-023-04018-w [3] Xiaojing Huang et al., "Optimization of overlap uniformness for ptychography", Opt. Express 22, 12634-12644 (2014). https://doi.org/10.1364/OE.22.012634 [4] Filippo Baruffaldi et al. Single-photon counting pixel detector for soft X-rays. Commun Phys 8, 321 (2025). https://doi.org/10.1038/s42005-025-02240-9 [5] Björn Enders et al., "Computational framework for ptychographic reconstructions", Proc. R. Soc. A.47220160640 (2016). http://doi.org/10.1098/rspa.2016.0640 [6] Pierre Thibault et al., “Probe retrieval in ptychographic coherent diffractive imaging,” Ultramicroscopy 109(4), 338–343 (2009). https://doi.org/10.1016/j.ultramic.2008.12.011[7] Pierre Thibault et al., "Maximum-likelihood refinement for coherent diffractive imaging," New J. Phys. 14 063004 (2012). https://doi.org/10.1088/1367-2630/14/6/063004 [8] Ryosuke Okuta et al. "Cupy: A numpy-compatible library for nvidia gpu calculations." Proceedings of workshop on machine learning systems (LearningSys) in the thirty-first annual conference on neural information processing systems (NIPS). Vol. 6. (2017). [9] Pierre Thibault and Andreas Menzel "Reconstructing state mixtures from diffraction measurements" Nature 494, 68–71 (2013). https://doi.org/10.1038/nature11806
Keyword(s):
MAX IV Laboratory; ptychography; SoftiMAX; X-ray.
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)