Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23292838# Underground LHD Trajectory Planning Benchmark v1.0 ## Purpose This release provides the minimum public benchmark needed to evaluate trajectory-planning methods on the same underground LHD occupancy grid and task definitions used in the associated study, **“Topology-Guided Continuous-Curvature Trajectory Planning for Articulated Autonomous Vehicles in Constrained Underground Environments.”** The benchmark is intended for reproducible comparison on a common map, common start/goal tasks, common vehicle/path constraints, and common evaluation definitions. Planner source code is not part of this minimal release. ## Dataset provenance The occupancy grid was constructed from mine-site data collected and processed by the authors within an engineering project. The released file contains only the geometric occupancy information required for trajectory-planning evaluation and is approved for public release. The released occupancy grid is the same geometric map used for the reported experiments. Authors: **Yongchun Liu** (first author) and **Pingan Peng** (corresponding author). License: **CC BY 4.0**. See `LICENSE`. Dataset DOI: **10.5281/zenodo.23292838** (https://doi.org/10.5281/zenodo.23292838). ## Contents ```text Underground-LHD-Trajectory-Planning-Benchmark-v1.0/ ├── README.md ├── LICENSE ├── CITATION.cff ├── maps/ │ ├── occupancy_grid.pgm │ └── map.yaml ├── benchmark/ │ ├── non_reversal_cases.csv │ └── vturn_cases.csv ├── parameters/ │ └── benchmark_parameters.yaml └── results/ ├── non_reversal_results.csv ├── reported_summary.csv ├── vturn_results.csv └── vturn_reported_summary.csv ``` ## Map and coordinates - Map size: **3080 × 970 pixels**. - Resolution: **0.2 m/pixel**. - Pixel value 255 (white): free space. - Pixel value 0 (black): occupied space. - Binarization used by the planner: pixel value `>= 128` is free. The experiment coordinate convention is: ```text x_world [m] = col_px * 0.2 y_world [m] = (970 - row_px) * 0.2 ``` Image rows increase downward, while world `y` increases upward. Heading is expressed in degrees, with `0 deg` along `+x` and positive angles counterclockwise. Map SHA-256: `d2436ce010c4786f59a062e5ceca89ed8ec6d15c6ace6b1cf6b64a76b7321c5d` ## Tasks `benchmark/non_reversal_cases.csv` contains 12 ordinary planning tasks: Groups 1–3 are single-drift cases, Groups 4–9 are multi-branch cases, and Groups 10–12 are grid-like cases. `benchmark/vturn_cases.csv` contains the nine mandatory direction-reversal cases (Groups 4–12). Group 7 uses start/goal headings **-90 deg / +90 deg**. ## Main constraints - Vehicle width: **2.45 m**. - Nominal safety margin: **0.5 m**. - Nominal safety radius: **1.725 m**. - Design speed: **2.0 m/s**. - Curvature bound: **0.22 m^-1**. - Sharpness bound: **0.05 m^-2**. The experimental planner directly uses the curvature and sharpness bounds as fixed path-domain constraints. The articulation geometry and nominal operating parameters used to motivate these bounds are recorded in `parameters/benchmark_parameters.yaml`. ## Evaluation definitions Normalized length is `L / L_E`, where `L_E` is the Euclidean distance between the benchmark start and goal. For path-composition statistics, straight samples satisfy `|kappa| <= 0.002 m^-1`; circular-arc samples satisfy `|kappa| > 0.002 m^-1` and `|d kappa/ds| <= 0.0005 m^-2`; remaining samples are classified as curvature-varying. Isolated segments shorter than 0.2 m are merged according to the rule specified in the parameter file. Curvature/sharpness compliance uses a numerical tolerance of `1e-9` only to avoid floating-point round-off at analytical limits. Safety compliance requires clearance `>= 1.725 m`. ## Non-reversal reference results `results/non_reversal_results.csv` contains case-wise reference statistics exported from the evaluation outputs. For RRT*, `success_count` is taken from the independent 20-run success/runtime records; across all cases these records contain **227/240 = 94.6%** successful runs. The manuscript-level rounded checks are provided separately in `results/reported_summary.csv`. Small differences can occur if case-wise exports are re-aggregated directly because the original analysis uses the full evaluation arrays and different weighting for deterministic versus stochastic outputs. ## V-turn reference results The public release contains the HHA V-turn experiment for which verifiable raw records are available: the **3600-s diagnostic budget**. No 10-s HHA result is included in this release. HHA returns feasible solutions for **5/9** cases (Groups 4–8), while the proposed method solves **9/9** cases. `results/vturn_results.csv` provides case-wise records derived from the available experiment files. `results/vturn_reported_summary.csv` records the manuscript-level rounded values (HHA: 30.70 s and 1.712 over its five successful cases; Ours: 22.10 ms and 1.265 over all nine cases). ## Notes on reproducibility 1. The map, task coordinates/headings, path-domain constraints, metric definitions, and case-wise numerical results are public in this package. 2. The baseline post-processing protocol is described in `parameters/benchmark_parameters.yaml`. HHA retains its original pipeline; A*, RRT*, and Sk-A* use the same downstream smoothing procedure employed in HHA. 3. Exact source implementations are not included in this minimal data release. 4. The package contains reference results for comparison; researchers can run their own planners on the same benchmark and compute the same metrics using the definitions above. ## Citation Please cite the associated article and this dataset. Dataset DOI: **10.5281/zenodo.23292838** (https://doi.org/10.5281/zenodo.23292838).
Keyword(s):
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)