Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23296145Combined and unfiltered logger data from radiometer measurements of global shortwave irradiance and longwave irradiance at Nangis (Départment 77) in the rural area to the SE of Greater Paris recorded during the urbisphere Paris Campaign from 2023-01-26 00:00 to 2024-03-27 00:00 UTC. Measurements were taken at the MétéoFrance weather station at Nangis on the airfield at Nangis-les-Loges LFAI (ID 77211001) at 48.595124°N / 3.007791°E. Radiometer measurements taken at PANANG are: Global (solar) hemispherical irradiance (GHI) with an intermittently ventilated Kipp&Zonen CM21 pyranometer Longwave hemispherical irradiance (LHI) with an intermittently ventilated and Kipp&Zonen CG1 or CG4 pyrgeometer (from 2023-01-26 18:00:00 to 2023-03-22 15:00:00 a CG4 pyrgeometer was operated, from 2023-03-22 15:15:00 to 2024-03-27 13:04:00 a CG1 pyrgeometer was operated). The values in this dataset are calibrated using manufacturer calibrations for all instruments and no further quality controlls or gap filling procedures have been applied. For quality controlled and calibrated data use L1 data and higher instead. The two L0 datafiles (RAW_1min, MET_1min) combine all individual (uncalibrated voltage and manufacturer calibrated) logger files (automatic transfer, manual download) with a consistent and consecutive time axis. Missing data is filled with -9999. Each data file is structured with time steps as rows and parameters as column in comma-separated csv format. The columns contain readings from two radiometers and a co-located T/RH sensor (Campbell Scientific HygroVue 10) and Surface brightness temperature measured (Campbell Scientific IR120 IRT Thermometer) pointing to the grass surface. Files have 4 header lines following the Campbell Scientific Inc. TOA5 file definition. The L0 data combined all individual file transmissions files into a single .csv file covering the entire period of observations at PANANG. The individual logger output files (source of this dataset) can be found here: Morrison, W., Hilland, R., Looschelders, D., Legain, D., Masson, V., Zeeman, M., Grimmond, S., & Christen, A. (2024). Data from Radiometer (RAD) measurements at Paris – Nangis (PANANG) from 2023-01-26 to 2024-03-27 [RAW] (Version v1.0.2) [Dataset]. Zenodo. https://doi.org/10.5281/zenodo.12967562 File "PANANG-MET_1min-202301260000_202403280000_UTC.csv" contains the manufacturer calibrated physical values: Column descriptions: TIMESTAMP: Time / Date of the end of the aggregation interval in UTC in format YYYY-MM-DD hh:mm:ss RECORD: Continuous internal record number MET_PYRG_LHI_Wm2_Avg: Average longwave hemispherical irradiance in W/m2 measured with an intermittently ventilated thermopile pyrgeometer (Kipp & Zonen CG3 or CG1) MET_PYRG_LHI_Wm2_Std: Standard deviation of longwave hemispherical irradiance in W/m2 measured with an intermittently ventilated thermopile pyrgeometer (Kipp & Zonen CG3 or CG1) MET_PYRA_GHI_Wm2_Avg: Average global (solar) hemispherical irradiance in W/m2 measured with an actively intermittently thermopile pyranometer (Kipp & Zonen CM21) MET_PYRA_GHI_Wm2_Std: Standard deviation of global (solar) hemispherical irradiance in W/m2 measured with an intermittently ventilated thermopile pyranometer (Kipp & Zonen CM21) MET_HV10_AirTemperature_degC_Avg: Air temperature in °C measured with T/RH probe in screen (Campbell Scientific HygroVue 10) MET_HV10_RelHumidity_percent_Avg: Relative humidity in % measured with T/RH probe in screen (Campbell Scientific HygroVue 10) MET_HV10_VapourPressure_hPa_Avg: Vapour pressure in hPa calculated based on air temperature and relative humidity measured with T/RH probe in screen (Campbell Scientific HygroVue 10) MET_HV10_DewPoint_degC_Avg: Dew point in °C calculated based on air temperature and relative humidity measured with T/RH probe in screen (Campbell Scientific HygroVue 10) MET_HV10_VapPressDeficit_hPa_Avg: Vapour pressure deficit in hPa calculated based on air temperature and relative humidity measured with T/RH probe in screen (Campbell Scientific HygroVue 10) MET_IR1201_BrightnessTemp_degC_Avg: Average brightness temperature of surface in °C measured using an infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 1 MET_IR1201_BrightnessTemp_degC_Std: Average brightness temperature of surface in °C measured using an infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 1 MET_IR1201_BrightnessTemp_degC_Max: Average brightness temperature of surface in °C measured using an infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 1 MET_IR1201_BrightnessTemp_degC_Min: Average brightness temperature of surface in °C measured using an infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 1 MET_IR1202_BrightnessTemp_degC_Avg: Average brightness temperature of surface in °C measured using an infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 2 (not installed, empty) MET_IR1202_BrightnessTemp_degC_Std: Average brightness temperature of surface in °C measured using an infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 2 (not installed, empty) MET_IR1202_BrightnessTemp_degC_Max: Average brightness temperature of surface in °C measured using an infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 2 (not installed, empty) MET_IR1202_BrightnessTemp_degC_Min: Average brightness temperature of surface in °C measured using an infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 2 (not installed, empty) Missing data are shown with -9999. Missing data and data gaps are summarized in "PANANG-MET_1min-202301260000_202403280000_UTC_missing_data_report.txt" File "PANANG-RAW_1min-202301260000_202403280000_UTC.csv" contains the raw voltage and auxilliary measurements such as pyrgeometer temperature: Column descriptions: TIMESTAMP: Time / Date of the end of the aggregation interval in UTC in format YYYY-MM-DD hh:mm:ss RECORD: Continuous internal record number RAW_Cr1000_Voltage_V_Min: Minimum battery voltage measured on the CR1000X data logger RAW_Cr1000_PanelTemp_degC_Avg: Average panel temperature on the CR1000X data logger RAW_PYRG_LHI_Signal_mV_Avg: Average voltage signal of the ventilated thermopile pyrgeometer (Kipp & Zonen CG3 or CG1) RAW_PYRG_LHI_Signal_mV_Min: Min voltage signal of the ventilated thermopile pyrgeometer (Kipp & Zonen CG3 or CG1) RAW_PYRG_LHI_Signal_mV_Max: Max voltage signal of the ventilated thermopile pyrgeometer (Kipp & Zonen CG3 or CG1) RAW_PYRG_LHI_Signal_mV_Std: Standard deviation of the ventilated thermopile pyrgeometer voltage signal (Kipp & Zonen CG3 or CG1) RAW_PYRG_SHI_Signal_mV_Avg: Average voltage signal of the ventilated thermopile pyranometer (Kipp & Zonen CM21) RAW_PYRG_SHI_Signal_mV_Min: Min voltage signal of the ventilated thermopile pyranometer (Kipp & Zonen CM21) RAW_PYRG_SHI_Signal_mV_Max: Max voltage signal of the ventilated thermopile pyranometer (Kipp & Zonen CM21) RAW_PYRG_SHI_Signal_mV_Std: Standard deviation of the ventilated thermopile pyranometer voltage signal (Kipp & Zonen CM21) RAW_PYRG_RS_R0_Avg: Average resistance ration RS/R0 of the temperature measurement on the body of the thermopile pyrgeometer (Kipp & Zonen CG1) RAW_PYRG_BodyTemp_degC_Avg: Average temperature in °C of the body of the thermopile pyrgeometer (Kipp & Zonen CG1) RAW_PYRG_BodyTemp_degC_Min: Average temperature in °Cof the body of the thermopile pyrgeometer (Kipp & Zonen CG1) RAW_PYRG_BodyTemp_degC_Max: Average temperature in °Cof the body of the thermopile pyrgeometer (Kipp & Zonen CG1) RAW_PYRG_BodyTemp_degC_Std: Standard deviation in °C of the temperature of the body of the thermopile pyrgeometer (Kipp & Zonen CG1) SYS_SW12_1_ON: Whether the switch #1 for the fans is on or off. SYS_SW12_2_ON: Whether the switch #2 for the fans is on or off. RAW_HV10_AirTemperature_degC_Avg: Unfiltered digital air temperature submission from the T/RH probe (Campbell Scientific HygroVue 10) RAW_HV10_RelHumidity_Percent_Avg: Unfiltered digital relative humidity in % submission from the T/RH probe (Campbell Scientific HygroVue 10) RAW_IR1201_ThermopileVoltage_mV_Avg: Voltage signal of the thermopile of the infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 1 RAW_IR1201_ThermistorVoltage_mV_Avg: Voltage signal of the thermistor of the infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 1 RAW_IR1201_ThermistorTemp_degC_Avg: Signal of the thermistor of the infrared thermometer pointing to the grass surface converted to °C (Campbell Scientific IR120 IRT Thermometer) number 1 RAW_IR1202_ThermopileVoltage_mV_Avg: Voltage signal of the thermopile of the infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 2 (not installed, empty) RAW_IR1202_ThermistorVoltage_mV_Avg: Voltage signal of the thermistor of the infrared thermometer pointing to the grass surface (Campbell Scientific IR120 IRT Thermometer) number 2 (not installed, empty) RAW_IR1202_ThermistorTemp_degC_Avg: Signal of the thermistor of the infrared thermometer pointing to the grass surface converted to °C (Campbell Scientific IR120 IRT Thermometer) number 2 (not installed, empty) Missing data are shown with -9999. Missing data and data gaps are summarized in "PANANG-RAW_1min-202301260000_202403280000_UTC_missing_data_report.txt"
Keyword(s):
2023; 2024; 77211001; Brightness temperature; Département 77.
MeSH Term(s):
Grants and Funding:
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)