Loading...
Loading...
Contributors:
Dataset URI:
10.6084/m9.figshare.32319159.v1DATASET INFORMATIONAn electroencephalography (EEG) dataset collected from 19 stroke patients that underwent up to 30 therapy sessions during the ReHand-BCI clinical trial (registration: NCT04724824, https://doi.org/10.3389/fnins.2025.1579988), using a Brain-Computer Interface (BCI) system developed for upper extremity (UE) motor rehabilitation, is presented. The dataset also includes the participants’ demographic and clinical information, trial-related annotations consisting of artifact presence and ReHand-BCI feedback information, and clinical assessments scores for UE motor function evaluation, specifically the FMA-UE and the ARAT scores.This data is intended to support diverse research applications, including the characterization of stroke-related brain dynamics, the development of EEG-based biomarkers of UE motor recovery, the evaluation of EEG signal-processing methods, the training and testing of machine learning models, and the development of BCI or neurofeedback systems.ParticipantsTen participants were allocated to the experimental group, where the BCI was controlled by the participants’ motor intention (MI) of their paralyzed hand by performing the intent of a grasping task to activate a robotic hand orthosis, providing passive finger flexion and extension. The control group was comprised by 9 participants who received a sham-BCI intervention, where the robotic orthosis activated randomly without depending on the user’s MI. In each therapy session, participants performed up to 80 MI-based trials, while raw EEG was acquired from 16 electrodes located over the motor cortex of both brain hemispheres.ReHand-BCI systemThe ReHand-BCI system consisted of a computer monitor that provided instructions, in the form of visual and auditory cues, to the patients and three stages: acquisition, processing, and feedback. The acquisition stage was comprised by a g.USBamp amplifier (g.tec medical engineering GmbH, Austria), a g.GAMMAbox preamplifier (g.tec), and 16 g.LadyBird active electrodes (g.tec). EEG data was acquired at 256 Hz with a 24-bit A/D resolution. The electrodes were located at the F3, FC3, C5, C3, C1, CP3, P3, FCz, Cz, F4, FC4, C6, C4, C2, CP4, and P4 positions using an EEG cap marked with the 10-10 system of a size that fitted the participants’ head and centred around the Cz position. A monopolar recording was performed with an active ground electrode placed on the AFz position and a passive reference electrode placed on the right earlobe. The processing stage, implemented in a Precision 5820 workstation (Dell Inc., Texas, USA) and programmed in a MATLAB R2017a (MathWorks Inc., Massachusetts, USA) Graphical User Interface, consisted in two modes, an offline calibration mode and an online therapy mode. For calibration, previously recorded EEG data from the preceding therapy session was used to determine subject-specific parameters. These features were selected via Particle Swarm Optimization to determine relevant Common Spatial Patterns parameters extracted from the 8–12, 12–16, 16–20, 20–24, 24–28, and 28–32 Hz frequency bands of the prerecorded EEG data, following the Filter Bank Common Spatial Patterns framework. Lastly, the selected features were used to train a Linear Discriminant Analysis for task classification purposes.In the therapy mode, 1 s windows of EEG data acquired online were classified as either hand MI or as rest using the selected subject-specific parameters obtained in the calibration mode. The feedback stage consisted in a robotic hand orthosis that provided to the participant's paralyzed hand passive finger flexion and extension. The robotic orthosis was activated via a Bluetooth command sent by the processing stage if the system detected the user’s hand MI for the EG, or randomly if the participant was allotted to the CG. Further technical details of the ReHand-BCI system can be found in previous studies (https://doi.org/10.1155/2018/1624637, https://doi.org/10.3389/fnbot.2023.1015464).Therapy sessionsAll participants received up to 30 1-hour therapy sessions, provided daily from Monday to Friday for a total of 6 weeks. Participants performed 4 runs of 20 trials each in every therapy session.Outcome measuresPrimary outcome measures were two clinical assessments: the FMA-UE, which evaluates UE sensorimotor function (https://doi.org/10.1177/1545968313491000), and the ARAT, which measures UE functional performance (https://doi.org/10.1016/j.apmr.2006.09.003). A clinical assessment session was performed at baseline (T0), after the 15th therapy session (T1), and after the intervention (T2), for a total of three evaluations. For every participant, the same expert clinician performed all 3 assessments sessions, who remained blinded to group allocation throughout the intervention period.DATASET DESCRIPTIONThis dataset is fully described in the article "A multi-session EEG and upper extremity assessment dataset during stroke rehabilitation with the ReHand-BCI".The dataset is comprised by an .xlsx file named “Participants_Information.xlsx” and by ZIP files named after the participants’ ID. The coded demographic and clinical information of the participants is provided on the “Information” sheet of the .xlsx file, whereas the corresponding codes can be found on the “Coding” sheet. Each ZIP file contains two folder levels and, inside the second-level folder, Comma-Separated Values (CSV) format files. For every participant, EEG data acquired during each therapy session and the FMA-UE and ARAT scores obtained from the three clinical assessments were included in the dataset. At the first folder level after decompressing the ZIP files, folders state the participants’ ID, with the second level folders named either as the therapy session number (S1, S2, …, or S30) or as the clinical assessment session number (T0, T1, or T2).Electroencephalography dataIn the therapy session folders, the acquired EEG data can be found in CSV format files, divided by completed runs. The filename of the CSV EEG data is comprised by the participant’s ID, the therapy session number, and the run number. For instance, for participant P4, therapy session S15, and run 3 (R3), the filename is “P4_S15_R3.csv”. In the clinical assessment session folders, two CSV files can be found, each one containing the clinical score of either the FMA-UE or the ARAT assessment of the corresponding session. The names of these files are comprised by the participant’s ID, the assessment session number, and the clinical evaluation abbreviation. For example, for participant P12, clinical assessment session T2, and for the FMA-UE score (FMAUE), the filename is “P12_T2_FMAUE.csv”.If a participant did not attend a therapy session, the corresponding folder is absent from the database. Additionally, if a participant performed, due to time constraints, only 3 runs in a therapy session, three EEG CSV files are found in the corresponding folder. Participant P2 performed eight 10-trial runs, instead of the standard four 20-trial runs, from therapy session S12 to S30 due to patient’s fatigue.The therapy session CSV files comprise 19 rows. The first row contains labels that denote the trial period to which every sample (column) belongs to in the continuous EEG recording for each run. The rest period (0 to 4 s of the trial’s time structure) was denoted as “Rs”, the MI period (4 to 9 s) was designated as “MI”, the relaxation period (9 to 14 s) was referred to as “Rl”, and the random interval period was denoted as “Rn”. Thus, for example, a sample (column) that belongs to the 17th trial (T17), in the relaxation period (Rl), of a participant whose affected hand was the right (R) hand, has the label “T17_Rl_R” in the first row of that particular column. Row 2 contains coded characters to indicate if the trials were removed (r) or kept (k) to perform the cortical activity longitudinal analysis presented in the Technical Validation section. These characters only appear in the first column of each trial, with the remaining columns left blank. Row 3 indicates the output value of the ReHand-BCI’s processing stage in the rest and the MI periods. A value of 1 indicates that the system’s Linear Discriminant Analysis classified the previous 1 s EEG window as “MI”, whereas a value of 0 reflects a “rest” classification. These values are found in the column after each 1 s EEG window of the rest (at 1, 2, 3, and 4 s) and the MI (at 5, 6, 7, and 8 s) periods. The remaining columns in the row are blank. Rows 4 to 19 contain the acquired raw EEG electrode signals in the following order, which corresponds to their original electrode configuration: F3, FC3, C5, C3, C1, CP3, P3, FCz, Cz, F4, FC4, C6, C4, C2, CP4, and P4. Each column in these rows represents a sample value acquired from each EEG electrode expressed in µV and without filtering, thus being raw data. The number of columns differ in the CSV files due to the random duration of each trial.Clinical assessments dataEach clinical assessment session CSV file contains two rows and one column. The first row shows a label that is comprised by the session number and the clinical scale abbreviation. For example, the label of the T1 ARAT score is “T1_ARAT”. The second row shows the obtained score in the clinical assessment.
Keyword(s):
Action Research Arm Test; Brain-Computer Interface; Electroencephalography; Fugl-Meyer Assessment-Upper Extremity; Neural engineering.
MeSH Term(s):
Grants and Funding:
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)