10.5281/zenodo.23318457This dataset contains processed steady-state measurements from a laboratory small-hydropower platform used to investigate the effect of generator magnetic flux on electrical energy-conversion performance. The test system incorporates a pump–turbine mechanically coupled to a 4 kW converter-fed induction machine operated as a generator. The master workbook contains 131 steady-state operating points measured at 10 nominal power levels from 0.40 to 3.50 kW. During each power sweep, the commanded magnetic-flux setpoint was varied from approximately 50% to 120% of rated flux, while the generator shaft operated approximately near 1500 rpm. The realized magnetic flux, shaft speed, torque, mechanical and electrical power quantities, inverter efficiency, diagnostic efficiency ratios, and inverter loss are included.