Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23334461This repository contains the supplementary datasets associated with the research paper titled “Bridging the Cognitive Gap in Task Mining: Identifying Physiological Metrics for Cognitive Load Estimation in Office Work Environments”. Two complementary datasets are deposited, corresponding to the two axes along which the study orders the literature. The FullTable_Supplementary_Material_Physiological_Metrics_CWL_Office_RQ1_RQ2.xlsx file covers the first axis: which physiological metrics the reviewed literature reports as estimators of Cognitive Load (CL), and how strongly each is supported. This Excel file consolidates 179 physiological metrics grouped into 11 physiological categories, extracted from the 47 literature reviews included in a tertiary review of 88 retrieved records. It is the primary source of Figures 2 to 7 and of Tables A1 to A5 (Appendix A) of the manuscript, and it contains three sheets: Table, CL_Relevance and Evidence. The Table sheet contains one row per metric, with the following variables: Metric: The name of the physiological metric as reported in the literature (e.g., “Pupil Diameter (PD)”). Category: The physiological grouping the metric belongs to (e.g., “Eye Tracking”). Subcategory: The specialized subgroup within the category, where applicable (e.g., “Pupillometry”). ID: A unique identifier assigned to each metric (e.g., “EYE01”), used throughout the manuscript to cross-reference metrics between text, tables and figures. Sources: The number of included reviews that name the metric (N in the manuscript). CL Relevance (1, 2, 3): The three-level label computed in the CL_Relevance sheet, where 3 corresponds to the highest level. Publication Year Median: The median publication year of the reviews that name the metric. A secondary block on the same sheet reports two statistics per category, Mean value of sources per metric and Median Year of Sources, followed by a numbered legend of the 54 documents assessed against the third exclusion criterion (EC3), with first author, publication year and type of study. The seven rows highlighted in red (six primary studies and one workshop report) were excluded by that criterion; the remaining 47 secondary studies form the corpus, and their numbers are the document IDs used in both files. The category mean is the threshold of the first premise of the CL Relevance procedure. The CL_Relevance sheet makes every step of the procedure (Equation 1 of the manuscript) explicit. For each metric it reports the number of sources N, the category mean, Premise I (N exceeds the category mean), the numbers of supportive and not supportive sources, the proportion p_s = supportive / (supportive + not supportive), Premise II (p_s ≥ 2/3), the resulting label and the document IDs of its sources. A metric receives 3 when both premises hold, 2 when one holds and 1 when neither does. Sources classified as mentioned count in N and do not enter p_s; when no source evaluates a metric, p_s = 0. The supportive and not supportive counts are computed from the Evidence sheet, so changing a class there, or the 2/3 threshold in the Premise II column, recomputes the labels. The Evidence sheet contains one row for each of the 1,059 review-metric pairs, with the document ID, first author, publication year, metric ID and name, the class of the evidence the review reports, the page of the review’s PDF and the passage that supports the class. A pair is supportive when the review concludes, or reports findings of the studies it reviews, that the metric responds to CL; not supportive when it reports contrary, null, mixed or explicitly uncertain evidence; and mentioned when the review names the metric without any statement on its sensitivity. Mixed evidence follows the conclusion the review draws for the metric; without such a conclusion, the balance of the reported findings decides, and ties count as not supportive. Statements about a whole modality classify the metrics the review names in the direction they indicate, unless metric-level evidence in the same review says otherwise. The file contains 547 supportive, 181 not supportive and 331 mentioned pairs. Conventions. A review is a source of a metric when its text names the metric by its name, an abbreviation or a synonym; mentions in search strings, eligibility criteria, abbreviation lists or reference lists do not count. Generic mentions of electromyography, fNIRS and fMRI count as sources of EMG amplitude (EMG01), the cerebral oxygenation change (NIMG03) and the BOLD signal (NIMG04), respectively. Eight pairs of document 1 (EYE02, EYE04, EYE06, EYE07, EYE08, EYE17, NE08 and NE11) are exceptions: the review names the parameter group or the hormonal assay, its metric-level tables are in a supplement that the PDF does not include, and these pairs take the class of the group-level statement. Square brackets in a passage mark content that the authors reconstructed or counted from the PDF: [..., transcribed] for a table cell whose extracted text was scrambled, checked word by word against the PDF page; [..., transcribed from image] for text inside a figure or a table inserted as an image; and [..., counted] for totals counted from the studies listed in a table cell. Context and Usage. Researchers can use this dataset to identify which physiological indicators of CL are best supported by the literature, to trace each label back to the passages that support it, and to recompute the labels under alternative definitions of the premises. Of the 179 metrics, 28 attain the highest label, 97 the intermediate level and 54 the lowest. The FullTable_Devices_RQ3.xlsx file covers the second axis of the study: with which devices the physiological metrics can be acquired, and which of those instruments a worker can use without interrupting the task. It complements the metric catalog deposited alongside it. This Excel file contains three sheets. The Table sheet consolidates 48 device types distributed across the same 11 physiological categories used in the metric catalog, drawn from 162 distinct manufacturer-and-model designations reported by 18 of the 47 included reviews; three designations are generic variants (PC webcam, PC microphone and saliva sampling kit). The Criteria sheet defines the three suitability criteria and the rules applied when grading. The Document References sheet lists the 18 reviews that report devices, with their document IDs in the metric catalog. This dataset is the primary source of Tables 3 and 4 and of the device catalog in Table B1 (Appendix B), and, together with the metric catalog, of Table 5. The Table sheet contains one row per device type, with the following variables: Category: The physiological grouping the device type belongs to. Consolidation was performed within categories, so a single commercial product that measures signals of two categories yields two device types. Subcategories / Metrics: The subcategories or metrics of the companion catalog that the device type can acquire. This column is what allows the two datasets to be cross-referenced. Sensor Device Type: The consolidated acquisition technology (e.g., “Smart ring (PPG)”), which is the unit of analysis of this catalog. Example models: The manufacturer-and-model designations reported in the included reviews for that device type. C1 (Contact and placement): Graded A, B or C according to the physical demands the device places on the worker, from contactless instrumentation to devices that prevent the activity from being performed normally. C2 (Operability): Graded A, B or C according to whether the worker can operate the device unaided, after simple preparation, or only with a trained technician. C3 (Provisioning): Graded A, B or C according to what the organization must supply, from hardware already present at the workstation to equipment requiring dedicated infrastructure or professional installation. Representative Image: A photograph of a representative product for each device type, embedded in the sheet. References: The document IDs of the reviews reporting each model, listed in the same order as the models themselves. Grading conventions. The three criteria are reported separately because they answer different questions: two concern the worker and one the organization. Grades apply to the device type of each row: a type that groups models with differing demands receives the grade of the most restrictive model reported in the included reviews, so the same product can carry different grades in different device types. Under this grading, 15 of the 48 device types receive no grade C in any criterion and are therefore deployable during ordinary office work. Context and Usage. Researchers and practitioners can use this dataset to determine which physiological signals are recordable in a given work setting, and at what cost to the worker and to the organization. Crossed with the metric catalog, it shows that 21 of the 28 metrics with the highest CL Relevance label can be acquired with at least one deployable device type. Readers who disagree with a particular grade can recompute the suitability profile of any device type directly from this file, without repeating the extraction.
Keyword(s):
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)