Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23368574Version 1.5 adds a synthesis note, "What the a0(z) tests say together: a falling g_obs/g_bar where the errors allow a test, and a fitted scale set by the baryonic and pressure inputs at R_e" (a0z_synthesis_note.pdf; scripts, outputs, figures, searches and audits in a0z_v1.5_SYNTHESIS.zip). It is exploratory and post hoc: it was designed after every result in the record was known, it is not preregistered, and it changes no scored label. It uses the record's frozen PIPE-2 and PIPE-3 code unchanged as a library. What it finds:- Shape. LEGA-C (147 galaxies), the one sample whose errors allow a shape test, prefers a ratio g_obs/g_bar that falls with g_bar (PIPE-3's R; classical margin 12, about one jackknife standard error above the threshold of 4) across gas multipliers 0-2, pressure multipliers 0.5-2 and stellar shifts -0.2 to +0.1 dex. MSA-3D's flat trend (18 galaxies) does not reappear.- Scale. No sample measures a0. At LEGA-C's accelerations the fitted a0 responds about three times as fast as the baryonic mass at R_e: locally d ln a0/d ln M* = -2.2, d ln a0/d ln M_gas = -0.6, d ln a0/d ln k_press = +0.8, explained by the interpolation function's leverage (L = 2.96). Shifts of +/-0.1 dex in stellar mass span a0 = 0.78-2.25. A universal a0 = 1.2 and an evolving a0 = 2.2 differ by about 0.13 dex in stellar mass, or a factor of four in inner gas. Every record value except MSA-3D's lies inside the ranges these inputs produce.- Matched in stellar mass, LEGA-C, KROSS and RC100 have median offsets from one RAR that are not distinguishable, although direct fits in the window differ. No dependence of a0 on stellar mass is detected inside any sample.- Reading: the record does not require an evolving a0; a0 at z ~ 1 cannot be read off until the baryonic mass at R_e is known to a few hundredths of a dex.- Can it be tested now? Searches (identifiers and counts only) found almost no CO or dust detections in the high-a0 samples (MSA-3D 0 of 23; MUSE-DARK 6 of its 126-galaxy parent). For the nine RC100 galaxies with PHIBSS CO, a preregistered test would decide with probability 0.07-0.13 (PIPE4_FEASIBILITY.md), so no test was run. Audits: three independent fresh-session audits. Round 1: 1 BLOCKER (the draft attributed the scale to cold gas; the stellar masses are the stronger lever), 7 MAJOR; round 2: 1 MAJOR (Table I's SPARC row); round 3: 0 BLOCKER, 0 MAJOR, 3 MINOR, all fixed. Every script and figure was reproduced byte for byte in each round. Findings and change logs are in synthesis/audit_r1-r3/. Files added in v1.5: a0z_synthesis_note.pdf (SHA-256 7b4493a02a8e857aa1f415f923b82fa088adf5b1df92b2b51febd1c4b9942606) and a0z_v1.5_SYNTHESIS.zip (SHA-256 be552c3bc715090559ef4e68500e5d5b8aabbdfb6243954b387d0a0b5f97f72f). Input catalogues are those already in v1.0 (RC100), v1.3 (KROSS) and v1.4 (LEGA-C). This computes the thermometer, not the engine; the inertia coupling remains unsolved. Version 1.4 adds PIPE-3 (scored 13 October 2026; folder pipe3/ inside a0z_v1.4_PIPE3.zip). PIPE-3 is a preregistered follow-on to PIPE-1 and PIPE-2. It asks whether an independent sample of star-forming discs at z ≈ 0.6–1 prefers the shape of the radial acceleration relation (RAR) or a constant dark-matter fraction (constant g_obs/g_bar) at the effective radius. Sample: 147 LEGA-C main-sample galaxies. Ionised-gas rotation velocities and dispersions are from Straatman et al. (2022, ApJ 928, 126), with the authors' asymmetric-drift correction applied (V_c² = v_rot² + 1.119 σ₀² at R_e). Effective radii are HST F814W Sérsic fits from LEGA-C DR3 (van der Wel et al. 2021). Stellar masses are surviving masses from BaStA (Gallazzi et al. 2026). Gas masses come from the Tacconi+18 (H₂) and Chowdhury+22 (HI, z ≈ 1) scaling relations. Baryonic accelerations use exponential thin discs. Gas errors are treated as recipe (Berkson) scatter; stellar-mass errors are analysed both as measurement noise and as recipe scatter, and a decisive label requires both to agree. The lock went through five independent audit rounds and was frozen under SHA-256 at 2026-10-13T20:29:31Z, before any LEGA-C data value was seen. Two blind pre-fit checks were built into the code. A photometric check decides whether the catalogue masses are total or 2.1″-aperture masses; it reads photometry and masses only, no kinematics. A dynamical-mass consistency check confirms the velocities are not already pressure-corrected. The catalogues were then downloaded, checked against their ReadMes, parsed by two independent readers, and scored exactly once. A post-score audit reproduced the run byte for byte, and an independent reimplementation from the lock text reproduced every number and label. Pre-fit checks: all three mass codes were classified as total masses (photometric slopes +0.09, −0.07 and +0.06, against a threshold of 0.30), so the test ran in its two-sided form. The velocity check confirmed the published velocities are uncorrected for pressure support. Result: R, RAR shape preferred. Measurement-noise reading Δ = +12.0, recipe-scatter reading Δ = +42.5, against the preregistered threshold of 4; no fit at a bound. The free power-law slope is 0.68 ± 0.08 under the measurement-noise reading, consistent with the RAR's local slope (0.74), and 0.52 ± 0.06 under the recipe-scatter reading, significantly steeper. A constant ratio (slope 1) is excluded under both. 15 of 17 preregistered recipe variants also return R and none returns F; the two not scored are removing the pressure-support correction and applying an aperture correction to total masses. Reported with the result:- The operative margin is the measurement-noise Δ = +12, which is typical of a true RAR at the fitted parameters. The size of the recipe-scatter Δ is not added evidence.- Leave-one-out tests never change the label. Trimming extreme residuals can reduce the margin to below threshold, so the result is moderate rather than overwhelming.- The known route to a false R is stellar-mass measurement errors about twice those stated.- The result depends on the published pressure-support correction. Meaning: the flat dark-matter trend seen in PIPE-1 (MSA-3D) does not appear in this independent z ≈ 0.6–1 sample. PIPE-3 does not measure a0 (the fitted 1.44–1.51 × 10⁻¹⁰ m s⁻² is descriptive), does not test MOND against dark matter, and does not establish that a0 evolves. See pipe3/run/RESULT_PIPE3.md and pipe3/lock/PREREG_PIPE3_LOCKED.md. Files added in v1.4: a0z_v1.4_PIPE3.zip (SHA-256 0d1a4b42716254ea00307dc35541dcedd2544d5ace02d3d2f8570afdbe1d6d38). It contains:- the frozen lock package (code, power study, SPARC control, aperture-check validations, exposure and methods logs, all five pre-freeze audits);- the input tables and the VizieR archives as downloaded;- the check and score outputs;- the result note, the post-freeze log, and the result audit with its scripts. Version 1.3 adds PIPE-2 (scored 12 October 2026; folder pipe2/ inside a0z_v1.3_PIPE2.zip). PIPE-2 is a preregistered follow-on to PIPE-1. It asks whether an independent z ≈ 0.9 sample prefers the shape of the radial acceleration relation (RAR) or a constant dark-matter fraction (constant g_obs/g_bar) at the effective radius. Sample: 225 KROSS galaxies (KMOS Hα, 3D-Barolo rotation curves with pressure-gradient correction; no dark-matter halo enters the velocities), from the catalogue of Sharma, Salucci & van de Ven (2021, A&A 653, A20), served by CDS VizieR as J/A+A/659/A40. Baryonic accelerations were built from the catalogue's stellar and gas masses with exponential thin discs. Two mass-error treatments were preregistered, classical (measurement noise) and Berkson (scatter of the true mass about a recipe value), and a decisive label required both to agree. The lock went through three independent audit rounds and was frozen under SHA-256 at 2026-10-12T00:52:42Z, before any KROSS data value was seen. The catalogue was then downloaded, checked, parsed by two independent readers, and scored exactly once. A post-freeze audit reproduced the run byte-for-byte, and its independent reimplementation matched every result to within 0.001. Result: I, inconclusive. The classical treatment prefers a constant ratio (Δ = −7.2) and the Berkson treatment prefers the RAR shape (Δ = +9.0), each beyond the preregistered threshold of 4. The same split appears across all ten preregistered recipe variants. The free power-law slope is 1.35 ± 0.38 under the classical treatment and 0.65 ± 0.10 under the Berkson treatment (the RAR's local slope is 0.65). Reported with the result: KROSS's measurement errors are larger than those in the power study's synthetic design, so the preregistered power and false-label rates are indicative only. The catalogue does not state how its 0.2 dex stellar-mass uncertainty divides between measurement noise and recipe scatter, and that division decides the shape. PIPE-2 therefore neither confirms nor refutes the flat dark-matter trend seen in PIPE-1 (MSA-3D). It does not measure a0, test MOND, or establish that a0 evolves. See pipe2/RESULT_PIPE2.md and pipe2/PREREG_PIPE2_LOCKED.md. Files added in v1.3: a0z_v1.3_PIPE2.zip (SHA-256 13390f9ffc49c0c0720b1c04ba14a0da752a6f3b1282a4697faf1093b27b4ffb). It contains the lock, its freeze record, the code, the power study, the SPARC control, the exposure and post-freeze logs, the input data (catalog1.dat and the archive as downloaded, from CDS VizieR J/A+A/659/A40), the scored output, the result note, and all four audits with their scripts. Version 1.2 adds PIPE-1 (scored 9 October 2026; folder pipe1/ inside a0z_v1.2_PIPE1.zip). This is a preregistered test of whether a third high-redshift sample follows RC100's pipeline or MUSE-DARK's value of a0. The record's two high-z estimates disagree: RC100 gives a0 ≈ 1.4 and MUSE-DARK III gives 2.0 to 2.7 (×10⁻¹⁰ m s⁻²). MSA-3D (Espejo Salcedo et al. 2026, arXiv:2606.27853) is a JWST/NIRSpec sample at 0.5 < z < 1.7. It was analysed with DysmalPy, the code RC100 used. PIPE-1 was locked under SHA-256 at 2026-10-09T09:27:41Z, before any MSA-3D table value was read. After the lock, the per-galaxy table was transcribed twice, in two separate sessions of the same AI model (Claude); the two outputs are byte-identical. The test was then scored exactly once, and the scored run was later reproduced byte-for-byte. A final audit reimplemented the fit from the lock text alone and matched the deposited numbers (a0 to 5 × 10⁻⁶). Result: S, MUSE-DARK value reproduced. On 18 usable golden-sample galaxies (5 of 23 excluded by the lock's prior-boundary flag rule, two of them with high dark-matter fractions; z_med = 1.07) the fitted a0 is 3.29 (1σ 2.77 to 3.95). The fit-quality differences are D = 26.8 for RC100's value, 19.9 for MUSE-DARK's value seen through RC100's mass offset, and 2.3 for MUSE-DARK's value. Both labelled secondaries also return S. Reported with the result: the fitted value lies above MUSE-DARK's (about 1.5σ), so S wins because the alternatives fit far worse, not because the data single out MUSE-DARK's number. The dark-matter fraction shows no detectable trend with acceleration (slope +0.04 ± 0.07, against −0.24 to −0.31 for every hypothesis), a shape none of the three models fits. The best-fitting mass offset has the opposite sign to RC100's. Post hoc and not tested: MSA-3D and RC100 sit at similar typical accelerations but have very different dark-matter fractions there (median 0.65 against 0.32); PIPE-1 does not say whether that reflects the samples, the mass models or a0. Through the record's frozen RAR machinery, MSA-3D's published dark-matter fractions (also derived with DysmalPy, the code RC100 used) do not return RC100's value. PIPE-1 does not measure a0, test MOND, establish that a0 evolves, or identify which part of a pipeline is responsible. See pipe1/README_PIPE1.md and pipe1/RESULT_PIPE1.md. Files added in v1.2: a0z_v1.2_PIPE1.zip (SHA-256 33b615b74aa0d43b23fedf5770cdd346723b0118f902543ad671fa76b9e21542); NOTE_TENSION_r4.md, the exploratory note hashed into the PIPE-1 lock; AUDIT_PIPE1_FINDINGS.md, AUDIT_PIPE1_r2_FINDINGS.md and AUDIT_PIPE1_r3_FINDINGS.md, the three pre-freeze audits cited by the lock. Their hashes are in pipe1/COMPANION_FILES_SHA256.txt. Four preregistered tests of whether the MOND acceleration scale a0 tracks the cosmic expansion rate. Each was SHA-256 hash-locked before the data were handled and scored exactly as locked. Two were scored. Option A, using the four binned a0 values published in MUSE-DARK III plus the SPARC z=0 anchor, returns O2: evolution is present but not horizon-shaped, a verdict that is fragile to an error-bar convention the source figure does not state; both readings are reported. RC100, using 100 rotation-dominated galaxies at z=0.6–2.5, returns O5: no model is adequate to the scatter, and within that, the horizon-shaped scaling is disfavoured against a constant a0 by ΔAIC 37. Two reconstruction attempts failed their calibration gates and were therefore not scored, as their locks require. Both are included with their gate output. The bundle contains the four locked preregistrations with their hashes, the analysis code, the scored results, the run logs, and a manifest. Third-party copyrighted material is deliberately excluded; see README_DEPOSIT.md. Version addition, 8 Oct 2026: EH-1. A preregistered scoring of the event-horizon shape a0(z) = A·R_E(0)/R_E(z) against both arms. Lock frozen 2026-10-08T18:45:19Z after two independent audits; not blind (all prior results declared). Result: RC100 E3 (event worse than constant by 8.4 AIC); MUSE-DARK E2 (worse than H(z) by 21.8, worse than linear by 35.1). Combined: UNRESOLVED. The two arms require incompatible amplitudes (0.99 vs 1.97), the record’s existing tension again. Files in EH1_deposit.zip; see RESULT_EH1.md. this computes the thermometer, not the engine; the inertia coupling remains unsolved.
Keyword(s):
acceleration scale; aperture correction; asymmetric drift; baryonic mass systematics; BaStA.
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)