Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23411104This dataset contains all the data for the article titled "Transient Resonant Peak Sequencing for Multiple-Leaks Localization: A Novel Graphical Framework". There has been a minor change in Figure ordering in the article. Figure 3a and Figure 3b refers to the FRF of the system with a single leak with xL/L = 0.1 and 0.14. Figure 12 a,b,c,d refers to the FRF of the system with two leaks denoted as validation case 1,2,3,4 with the leak ratio of 1.0. Figure 14 a,b,c,d refers to the FRF of the system with two leaks denoted as case 1,2,3,4 with the leak ratio of 0.8. Figure 16 a,b,c,d refers to the FRF of the system with two leaks denoted as case 1,2,3,4 with the leak ratio of 0.6.In the v.2 version, the following information are added:Validation where the leak ratio is 0.2 and 0.4Combined order table with the ratio of 0.2 and 0.4Distance ratio 0.2 and 0.4: The distance between the true leak locations with the closest bound of leak subdomainSensitivity result summary: Shows the summary of method's performance when the noisy data is consideredSensitivity case 1 realization 0: Example of noisy data used for suggesting alternative to the method in the existence of noiseCombined order table with ratio 1.0 sens: This is the combined order table assuming only four measurement points are consideredCombined metrics noisy / noiseless classification: This is the summary of recall, precision, and F1 score of different class for CatBoost model based on noiseless and noisy dataConfusion matrix noisy / noiseless classification: This is the confusion matrix of the CatBoost model based on noiseless and noisy dataRegression data ML: This is the result of regression based on CatBoost model given the leak locations are directly addedComparison_ITA_instance: The pkl file for ITA training instance In the v.3 version, the following information is uploaded:Combined metrics noisy/noiseless classification_fixConfusion matrix noisy/noiseless classifcation_fixA labelling error was noticed in the original csv file (label 1-10-11-12-...) where the label is ordered based on string. In reality, the true label (label 1-2-3-...) is ordered based on integer. The numeric value remains unchanged, but just the label is changed.Comparison_ITA_instance_makefairer: The pkl file for additional ITA training instance given an assumed leak ratio to make a fairer comparison. In the v.4 version, the following information is uploaded:Case 5, Case 6, Case 7, Case 8, Case 7*, and Case 8*: These are the data for sensitivity to small-leak assumption.Blind test 1, Blind test 2, Blind test 3, Blind test 4, and Blind test 5: These are the data for blind test. The answer key is indicated by _answerkey_Combined order table ratio 1.0 optimum measurement: The order table based on leak ratio 1.0 considering optimum measurement
Keyword(s):
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)