Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23400171Research-only materials for “Which Grid Cell Does a Short Dwell Read? Calibrating Dwell-Time Criteria for Metal-Oxide Gas Sensors on the Public RED:VAPOR Wind-Tunnel Grid”. The two original archives are retained unchanged. They contain analysis source, retained results and per-encounter tables, frozen criteria, numerical checks, and figure scripts. All 298 stored-number comparisons passed; five figures regenerated from retained results were byte-identical to the archived figures. The example-trace figure is supplied, with a generator requiring the upstream RED:VAPOR dataset (https://doi.org/10.5281/zenodo.18299926). Version 1.0.1 adds Redvapor_grid_sensitivity_addendum.zip, an existing-file sensitivity analysis of the observed grid under −log(raw Rs) versus the primary −log(Rs/R0) transform, using the same cells, windows, averaging times, and 2000 paired column-block bootstrap draws. The normalized baseline reproduced all 48 retained bootstrap arrays (maximum absolute difference 3.92e-13). The same original-window cases met all three counting conditions under both transforms: NH3 5/7, OX 4/7, and MiCS-5524 0/7. This is not numerical invariance: 14 of 384 interval-sign comparisons changed, 13 under board omission. With all boards, MiCS-5524 at 2 s in Experiment 3 changed from D = +0.208 [−0.005, +0.332] to +0.231 [+0.013, +0.343], but still failed the full counting condition. The addendum supplies a portable reproducer, source and input hashes, derived summaries, selected baseline arrays and bootstrap outputs, and all 14 changes. A clean run of its public reproducer matched all eight point/bootstrap output archives array-for-array. It does not recompute matched/symmetric surrogate correction, rank fidelity, simulator response or encounter results. Raw dataset archives, private caches and unrelated PersonTwin/Innerview product code are excluded. The two historical archives omit regenerable bootstrap intermediates; the new addendum includes the derived arrays needed for its sensitivity check. Historical scripts require path adaptation and earlier intermediate outputs; this release does not claim a fresh end-to-end experimental replay. No new physical, robot or simulator experiment, training run or model call was performed for this update. Original derived data and documentation are CC BY 4.0. Original research code is MIT except the identified GADEN-derived analysis engines, which are LGPL-3.0-only; complete source, attribution and license texts are supplied. Third-party rights remain unchanged. Existing SeoulTech research facilities were used. Generative AI assistance in code, analysis and drafting is disclosed in the manuscript and addendum. Seokjun Song is pursuing plans to commercialize PersonTwin/Innerview as a paid service. This record is research material, not a journal submission or acceptance.
Keyword(s):
dwell time; gas sensors; RED:VAPOR; reproducibility.
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)