Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23366169If you use this dataset, please cite it along with the original publication of Rodero et al. "Computational models show that functional remodeling, not anatomy, reshapes physiological determinants of cardiac performance in hypertrophic cardiomyopathy", Journal of Molecular and Cellular Cardiology (2026) https://doi.org/10.1016/j.yjmcc.2026.08.002. HCMn_unloading_light.tar.zst holds the unloading simulations of patient HCMn (n = 1 to 5), with one folder per sample (HCMn_unloading/unloading_i). Sample i uses the same parameter set as sample i of the closed-loop cardiac cycle simulations (related dataset). For HCM2, 142 samples numbered from 51 to 199 in the closed-loop dataset have no unloading simulation here. The .tar.zst files are tar archives compressed with Zstandard (for example, tar --zstd -xf HCM1_unloading_light.tar.zst). One unloaded configuration per sample, for every unloading simulation that wrote reference.bpts: 1077 (HCM1), 791 (HCM2), 1363 (HCM3), 1893 (HCM4) and 4733 (HCM5) simulations. This includes simulations that did not converge. For HCM1, 308 simulations that ran on a different mesh are not included. In two HCM3 samples, the procedure stopped after the first iteration: reference.bpts is empty in unloading_798 and incomplete in unloading_1178. In seven samples (HCM1 unloading_250, 259, 261 and 374; HCM5 unloading_4678, 4681 and 4687), part of unloading.log is overwritten with zero (NUL) bytes. unloading.log records the target end-diastolic volumes and pressures, the iteration history and whether the procedure converged. Starting from the imaged, pressurised geometry, an iterative unloading procedure estimates the stress-free reference configuration; the resulting reference node coordinates are stored in reference.bpts. When available (918, 766, 1071, 1742 and 3885 samples for HCM1 to HCM5), final_data/ holds the output of the last forward simulation, which inflates the reference configuration to the end-diastolic pressures: the chamber volumes (lv_endo.vol.dat, rv_endo.vol.dat, la_endo.vol.dat and ra_endo.vol.dat, in mL), the applied pressures (files ending in .nbc_p.dat, in kPa), the tissue volume (tissue.vol.dat, in mm³), vm.tdat, the solver logs (mechanics.log and electrics.log) and the solver iterations (mech_nsolve.dat, mech_lsolve.dat and par_stats.dat). In 51 HCM5 samples, final_data/ holds only some of these files. x.dynpt.tdat and debug.log are empty. In 51 HCM2 samples, final_data/ also holds vm.igb (transmembrane voltage at every node), and in 4 HCM2 samples and 567 HCM5 samples, final_data/current_data/ holds a second set of these output files, together with vm.igb. The anatomical mesh is not included: reference.bpts gives the unloaded node coordinates, in microns, in the node ordering of the four-chamber mesh (available in the related dataset). It is a CARP binary points file, with a 1024-byte text header giving the number of nodes, followed by the x, y and z coordinates of each node as little-endian 32-bit floats. Input parameters and values are included in final_data/parameters.par, except in the 51 HCM5 samples where final_data/ is incomplete.
Keyword(s):
cardiac digital twin; cardiac electromechanics; cardiac mechanics; CARP; computational cardiology.
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)