10.5281/zenodo.23439512Background. Acute electrical endpoints, pulmonary vein isolation, loss of local electrograms, non-inducibility, are achieved in almost every radiofrequency (RF), cryo and pulsed field ablation (PFA) procedure, yet conduction recovers in a substantial fraction of patients. Each modality has been enhanced to enlarge lesions: higher power and shorter duration, contact-force and dose indices for RF; second-generation and constant-pressure balloons, colder cryogens and tailored dosing for cryo; optimised waveforms, higher voltage, repeated applications and larger footprints for PFA. We asked whether these enhancements eliminate the tissue that is electrically silent at the end of the procedure but survives. Methods. Axisymmetric finite-volume models of a catheter or balloon on a myocardial slab 2–10 mm thick, with blood above and epicardial fat behind, were solved for 18 clinically representative settings, bipolar delivery between catheters on the two faces of the interventricular septum (6–15 mm, blood on both sides) was modelled separately, and a three-dimensional model of a circular multi-electrode bipolar catheter with real device electrode geometry was solved for seven further settings. RF was modelled with the Laplace and Pennes equations and Arrhenius damage; cryo with an enthalpy formulation including phase change; PFA with the Laplace equation and field-dependent conductivity, plus Joule heating. Tissue perfusion was present during energy delivery and absent afterwards. For each modality a lethal criterion (Arrhenius index Ω ≥ 1; minimum temperature ≤ −30 °C; field ≥ 636 V/cm, or 423 V/cm after repeated applications) and an acute-block criterion (Ω ≥ 0.1; tissue frozen; field ≥ 318 V/cm) defined the permanent lesion and the acutely blocked but surviving margin. Lesion lines were analysed through critical spacings for a lethal and for an acutely blocked midpoint. Results. Every setting produced a surviving margin. Its maximal lateral width was 0.8–2.9 mm for RF, 1.2–2.2 mm for cryo and 1.0–4.8 mm for PFA, and in 8-mm walls the surviving-to-lethal volume ratio ranged from 0.58 (repeated septal bipolar PFA) to 6.8 (double focal freeze). Enhancements that prolong or intensify the same field, longer RF duration, double or longer freezes, higher PFA voltage, larger footprint, deepened the lesion but widened the margin in absolute terms. Enhancements that concentrate dose, high-power short-duration RF and repeated PFA at a fixed outer field, narrowed the margin to 0.8–1.6 mm but did not remove it. In 3-mm walls, lines spaced more closely than a modality-specific critical spacing (3.8–6.8 mm for RF and ultra-low-temperature cryo; 7–20 mm for PFA) killed the midpoint, whereas a window of 1.6–8.0 mm beyond it produced midpoints that appeared blocked acutely but survived. In 8-mm walls no unipolar setting produced a transmural lethal line, and surviving but blocked tissue persisted at the midpoint for all settings. With catheters on both faces of the septum, the field between them produced a lethal zone at each face; septa up to 8 mm were transmurally lethal at 1000 V, but in thicker septa the zones were separated by an acutely blocked but surviving mid-septal layer (5.6 mm at 1000 V in a 12-mm septum; 6.6 mm at 1500 V and 1.8 mm at 2000 V in a 15-mm septum), and a lateral margin of 2.1–3.6 mm (1.0–1.8 mm with repeated applications) surrounded every septal lesion. With the circular bipolar catheter, lesions were shallower than with unipolar delivery and a 1.6–2.0-mm margin persisted across the line at all voltages (0.6–0.8 mm with repeated applications); in a 3-mm wall, 1000–1500 V left a 0.6–1.0-mm acutely blocked but surviving layer beneath the electrodes. Results were sensitive to lethal thresholds and to the tissue behind the wall but the margin persisted in all variants. Conclusions. Because energy fields decay continuously while the thresholds for temporary and permanent injury differ, a surviving but acutely silent margin accompanies every RF, cryo and PFA lesion, and current enhancement strategies relocate or rescale it rather than eliminate it. Whether it becomes a reconnection pathway depends on wall thickness and lesion spacing, which provides a mechanistic basis for spacing rules and for endpoints that discriminate stunned from destroyed tissue.
Keyword(s):
arrhythmia, ablation, radio frequency, cryoablation.
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)