10.5281/zenodo.23487328Run-to-failure collector-emitter voltage (VCE) records from DC power cycling of 20 discrete IGBTs (STMicroelectronics STGF7NB60SL, TO-220). Each device was cycled with a 1 s heating pulse and a 7.5 s off-period until catastrophic failure, at junction temperature swings of 65 to 128 K and lifetimes of 4,901 to 388,534 cycles. Each device has one CSV file with the raw VCE logged every 34 ms. During the off-period, VCE at a 100 mA sensing current acts as a junction temperature indicator. A summary table lists the test conditions, the junction temperature measured at the start of the test, and the cycles to failure for every device. These are the devices reported in Kim, Lee and Han, IEEE Transactions on Device and Materials Reliability, 2026 (doi: 10.1109/TDMR.2026.3706105). See README.md for the test setup, data format, calibration and notes on individual devices.