Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23482989What this is There are 249 independent runs of standard 2D Hasegawa–Wakatani at 26 values of C, from 1.9×10⁻⁴ to 10. Resolutions range from 128² to 1024², with up to 8 seeds per point. Only volume-averaged time series are stored, not fields. The record is meant as a reference for how the turbulent flux, the energy and the zonal-flow fraction behave across C, including the spread between seeds and between resolutions. Field snapshots at fixed parameters are published separately: N=512: https://doi.org/10.5281/zenodo.23480993 and https://doi.org/10.5281/zenodo.23480995 N=256: https://doi.org/10.5281/zenodo.23482812 and https://doi.org/10.5281/zenodo.23482814 Those field records use a different normalisation (fixed box, ∇⁶). Do not compare the dimensional numbers across the two directly. Model and normalisation The equations are standard HW: the adiabatic coupling acts on every mode, including the zonal ky = 0 row. Dissipation is Laplacian (∇²) on both vorticity and density, with ν = D: ∂ζ/∂t + [φ, ζ] = C (φ − n) + ν ∇²ζ ∂n/∂t + [φ, n] = C (φ − n) − κ ∂φ/∂y + D ∇²n , ζ = ∇²φ, κ = 1, μ = 0 The box and the dissipation are set from C through the linear dispersion relation, following Guillon & Gürcan (arXiv:2410.01406). Let γ_max be the maximum linear growth rate and k_y0 the wavenumber where it occurs. Then: box Lx = Ly = 2π·10 / k_y0, so the box holds 10 wavelengths of the most unstable mode; ν = D = 0.005 · γ_max / k_y0². ⚠ So every C has a different box size (44 to 600 ρs) and a different growth rate. γ_max is not monotone in C: it peaks near C = 0.2. A dimensional quantity scanned in C, such as Γₙ or E, mixes the effect of C with the change of box and time scale. Ratios, such as the zonal fraction ξ_k, are free of this. If you want a dimensional observable in growth-time units, divide by γ_max; index.csv gives γ_max, k_y0 and the box for every run. The choice of scaling can change the apparent shape of a curve in C, so state which one you use. Each run is a cold start from noise. Recording starts only after a measured saturation gate has been passed (the start time is in the attribute t_saturated). After that, 2000 time units (4000 samples, Δt = 0.5) or 4000 time units (8000 samples) are recorded. Time is in 1/ω_ci and lengths in ρs. The time integrator is ETD-RK4 with adaptive dt, in fp64. Files hw_ggnorm_standard_scan.zip holds one HDF5 file per run, hw_ggnorm_standard_C{C}_N{N}_s{seed}.h5, together with index.csv, which is also uploaded separately. dataset meaning t time gamma particle flux Γₙ = ⟨ṽ_x ñ⟩, with v_x = −∂φ/∂y (physical units) e_phys energy E = ½⟨|∇φ|²⟩ (kinetic) e_raw the same energy as an unnormalised spectral sum (e_phys = ½·e_raw/N⁴) xi_k zonal fraction: kinetic energy on the ky = 0 row divided by the total kinetic energy e_zonal, zonal_prod, zonal_shear zonal kinetic energy (same raw units as e_raw), zonal production P = ⟨R ∂ₓV⟩ (the Reynolds-stress drive), and rms zonal shear rms(∂ₓV). These are present in most but not all files; see the datasets column of index.csv All run parameters are stored as HDF5 attributes: C, N, seed, box_size, nu, D, kappa, k_fund, t_saturated, hw_model = "standard", gg_norm = 1, and others. The attribute source is a stale label from the base configuration; the box and ν actually used are in box_size and nu. index.csv has one row per run: the file name, C, N, seed, box, ν, k_y0, γ_max, the time span, the number of samples, and the record means of Γₙ, E and ξ_k. Coverage C range resolutions (seeds) 1.9×10⁻⁴ – 0.012 N=512 (1, or 3 at C = 0.012), N=1024 (3) 0.02, 0.03 N=1024 (3) 0.05 – 3, plus 5 N=128 (3), N=256 (3), N=512 (3–8), N=1024 (3) 1.75 N=512 (8), N=1024 (3) 4, 6 N=1024 (3) 8 N=512 (3), N=1024 (3) 10 N=512 (3) Resolution: what is converged and what is not The comparison is between seed-averaged record means at N=512 and N=1024, at the same C, box, ν and record length. The scatter between seeds is about 1% of the mean. ξ_k (zonal fraction) is converged to within about 6% at most C, and to 8% at C = 0.00075 and C = 8. ⚠ Γₙ is not converged, even at N=1024. N=1024 exceeds N=512 by 3–7% for C = 0.1–1.0, by 9–10% for C = 1.25–1.75, by 12–28% for C = 2–8, and by 8–14% for C ≤ 0.05. ⚠ E is not converged either. N=1024 exceeds N=512 by 12–49%; the gap is largest at the smallest C. N=128 and N=256 are far from converged in every dimensional quantity: at C = 1, Γₙ is 0.14, 0.28, 0.60 and 0.64 at N = 128, 256, 512 and 1024. Use them as a resolution ladder, not as values. Other caveats Single trajectories, finite records. At the smallest C the correlation times are long, so a 2000-unit record may hold only a few independent samples. Use the seeds for the error bar, not the within-run variance. ETD coefficient precision. The production integrator evaluates the ETD φ-functions in closed form, which loses accuracy for very slowly damped modes, mainly the zonal row. In a ∇² configuration at C = 0.01 a corrected integrator gave E and enstrophy 12–14% lower, at 1.7–3.2σ. That is suggestive but not established, and the effect on this scan has not been measured. Duplicates removed. Where a run had been saved twice, or later extended, only the longest record is included. The original file name is in the source column. Use and citation Licensed under Creative Commons Attribution 4.0 International (CC BY 4.0). If you use this data, please cite this record. It was generated with the Tulp Fusion Foundation JAX Hasegawa–Wakatani solver (public release planned). Checksums (md5) file md5 hw_ggnorm_standard_scan.zip d11aa7e4ec7ab171a82523d1c6ddd089 index.csv a1c6df0a34c242312255bfef731697be
Keyword(s):
direct numerical simulation; drift-wave turbulence; fusion; Hasegawa-Wakatani; parameter scan.
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)