Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23516565Version 7.44 (October 20, 2026) Version 7.44 adds Block H to the Contract Delivery sheet: what each plant’s cost is made of, in USD per MWh delivered over twenty years, for the four- and six-hour contracts. The lines are battery equipment, installation, operating cost, insurance at the base rate, the earthquake insurance surcharge, replacement cells, end of life and charging energy. Each line ties to the engine. The term “earthquake insurance surcharge” replaces “loading” throughout. The engine adds discount-rate tests at 3, 8 and 10 percent real, lithium end of life at zero, and the surcharge at 20 and 75 percent of the base premium. Result, for a utility-owned plant at 4.5 percent real, before federal tax credits: at four hours, lithium iron phosphate costs about USD 204 per MWh delivered and zinc-halide about USD 193 with the surcharge; without it the two are within a dollar. At six hours zinc-halide costs about USD 20 to 30 less. At 8 percent real, a merchant developer’s cost of capital, lithium is somewhat cheaper at four hours and zinc-halide still costs less at six. Earthquake insurance surcharge: LFP’s property insurance premium is raised by half, from 2% to 3% of installed cost a year, because one Cascadia earthquake could damage and ignite many lithium facilities at once. The surcharge is this report’s estimate, not a quoted rate, and is not applied to the non-flammable plant. Companion to Battery-Electric Oregon: Design for Resilience and Values, version 3.176, Appendix D. Version 7.43 (October 20, 2026) Version 7.43 changes the workbook’s headline method. A new sheet, Contract Delivery, sizes each chemistry to deliver the same contracted energy at the meter every dispatch for twenty years: 100 MW for four hours, with six- and ten-hour cases. It prices the charging energy each plant buys, and runs 44 scenarios covering price, degradation, depth of discharge, charging cost and the Oregon earthquake insurance loading. Result: delivering the same four-hour service over twenty years, lithium iron phosphate and zinc-halide cost the same. At six hours and longer, zinc-halide costs less, by about $20 to $30 per MWh. These figures use the manufacturer’s published performance. Zinc-halide would cost more only if its capacity faded at four times the published rate. Results are stated before federal tax credits. A new block adds the Section 48E investment credit in three cases: the 30% base rate for both, a domestic-content bonus for zinc-halide, and loss of the credit for LFP under the foreign-entity rules. In every central case the credits leave zinc-halide’s position unchanged or better. The zinc-halide price basis is inferred from the California Energy Commission record for the Camp Pendleton project and is stated with bounds. The LFP six-hour cost is interpolated between PNNL’s four- and ten-hour figures, a declared assumption. The LCOS, LCOS Engine and Sensitivity sheets are retained unchanged as a record of the earlier convention. Label corrections: the LCOS energy row now says what it computes, and the zinc-halide system is described as fan-ventilated. Correction The v7.42 headline, $221 per MWh for lithium iron phosphate against $167 for zinc-halide, overstated the difference. It reduced LFP’s delivered energy for depth of discharge and round-trip loss. But the NREL capital cost it used is priced per kWh of rated output, with those losses already inside the price, so LFP’s losses were counted twice. Version 7.43 corrects this by sizing both plants to deliver the same contracted energy. Statements derived from the v7.42 figures, including “about a quarter less” and the Oregon fleet savings figure, are being revised in the Battery-Electric Grid Report and its companion decks. Correction, September 2026. Version 7.42 corrects the capital cost basis used to compare lithium iron phosphate and zinc-halide storage. Earlier versions compared an installed cost for lithium against a bare equipment sale price for zinc-halide — not a comparable figure. This version enters capital cost as equipment cost plus engineering, procurement and construction, with the EPC figure held equal for both chemistries, from the National Renewable Energy Laboratory's published cost model. The correction narrows the twenty-year cost advantage for non-flammable chemistry; it does not reverse it. This workbook is the companion to Battery-Electric Oregon, corrected on the same basis (report v3.163). Chemistry-by-chemistry levelized cost of storage for utility-scale battery energy storage in Oregon, extended to full-life cost and then overlaid with the societal cost of fire. Compares lithium iron phosphate against non-flammable alternatives across capital cost, replacement schedule, augmentation, end-of-life cost and uninsured societal damage, so that a chemistry which is cheaper to buy can be tested against what it costs across its whole life. Every input is exposed on a Parameters sheet with its source, and assumptions are separated from sourced values throughout. Companion to Appendix D of Battery-Electric Oregon: Design for Resilience and Values (https://doi.org/10.5281/zenodo.22072669).
Keyword(s):
battery energy storage, Oregon, Cascadia Subduction Zone, grid resilience, lithium iron phosphate, energy policy, levelized cost of storage, sodium-ion, zinc-halide, iron-air, externality cost, non-flammable battery chemistry, least-cost, least-risk.
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)