Loading...
Loading...
Contributors:
Dataset URI:
10.60593/ur.d.34718643.v1This dataset contains benchtop urea clearance measurements for nanoporous silicon nitride (NPN) membrane hemodialyzers, generated under NIH NIDDK award R01DK126901.” The parent R01 tests the hypothesis that ultrathin NPN membranes, which are 100 to 1000 times thinner than conventional dialysis membranes, can clear enough toxin in a small device to support continuous, wearable hemodialysis. Earlier work in adenine-induced uremic rats showed that NPN membrane chips need at least 40 times less membrane area than polyethersulfone (PES) membranes to bring blood urea back to baseline. The R01 builds on that result in three aims: (1) design and characterize an NPN hemodialyzer using a benchtop small-animal mimic, (2) develop an NPN plasma-generating pre-filter, and (3) validate the combined device in benchtop simulations and in uremic Sprague-Dawley rats. The urea clearance studies fall under Aim 1, Activity 3 (Clearance/Retention Studies). Urea was the main small-molecule marker. Two experiment types were run: Single-pass: analyte and dialysate each flow through the device once. Inlet and outlet concentrations give the membrane’s instantaneous clearance (Kd). One example: blood-side flow 50 mL/min, dialysate flow 100 mL/min, urea about 35 mM in and 20 mM out, giving Kd ≈ 21 mL/min. Continuous recirculation: analyte and dialysate both recirculate in a closed loop until the two sides reach equal concentrations, which models a wearable system whose dialysate can’t be replaced. For example, 500 mL of 20 mM urea in PBS against 500 mL of PBS. The analyte matrices were urea-spiked DI water or PBS against PBS dialysate, and urea-spiked serum and whole blood against Fresenius dialysate. Urea was measured by colorimetric assay and reported in mM, as time courses and dialysate concentrations. The dataset includes the raw assay values, calculated concentrations, run notes (including device failures and chip reuse), and figures prepared for the annual progress reports. The data establish the transport performance of the NPN dialyzer before animal work. They are used to check predictions from the lab’s COMSOL Multiphysics model of device flow and diffusion, to size membrane area and treatment time toward clinical clearance targets (Kt/V ≥ 1.2), and to support the reduced animal cohort planned for the Aim 3 rat hemodialysis studies.
Keyword(s):
Biomedical and clinical sciences; Miniaturized Hemodialysis; Urea Clearance, Benchtop.
MeSH Term(s):
Grants and Funding:
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)