Loading...
Loading...
Contributors:
Dataset URI:
10.5281/zenodo.23236662Substrate preparation: TiO2(110) wafers were purchased from CrysTec GmbH Kristalltechnologie. The substrates were immersed in a Hellmanex III solution (Hellma GmbH) for 2 h, followed by ultrasonication in ethanol and isopropanol for 5 min each. The substates were then thoroughly rinsed with HPLC-grade water (Carl Roth) and dried under a stream of argon. Subsequently, the cleaned substrates were treated with an O2 plasma (Zepto, Diener Electronic) for 1 minute. The substrates were subsequently characterized by AFM. If contaminants were observed in the AFM images, the cleaning procedure was repeated until a clean surface was obtained. DNA origami adsorption: DNA origami triangles were synthesized as described in DOI 10.1039/d5lf00109a, after which the folding buffer was exchanged against 1x TAE buffer supplemented with 10 mM MgCl2, CaCl2, or SrCl2 during spin filtration. The samples were diluted to a concentration of 2.5 nM with the respective buffer solutions. A 50 µL aliquot of each DNA origami sample was pipetted onto the TiO2(110) wafer and incubated for 10 min to allow adsorption. The substrate was then rinsed with HPLC-grade water and dried under a stream of argon. EDTA exposure: The TiO2(110) wafers with adsorbed DNA origami nanostructures were incubated for 30 s in TAE buffer solutions of varying concentrations of 0.01x, 0.02x, 0.05x and 0.1x, respectively. The substrates were subsequently rinsed with HPLC-grade water and dried under a stream of argon. AFM: Atomic force microscopy (AFM) images in the dry state of inteact and denatured DNA origami triangles adsorbed on TiO2(110) surfaces were recorded using either a Bruker Dimension Icon operated in ScanAsyst mode with SCANASYST-AIR cantilevers (Bruker), featuring a nominal tip radius of 2 nm, or a JPK NanoWizard 2 or 3 operated in intermittent contact mode with HQ/Al BS cantilevers (MikroMasch), featuring a nominal tip radius of < 8 nm. Images were acquired over a scan area of 2 x 2 µm2 with a resolution of 1024 x 1024 pixels. XPS: X-ray photoelectron spectroscopy (XPS) survey spectra were recorded for as-received and plasma-cleaned TiO2(110) wafers, as well as after 10 min exposure to 10 mM solutions of MgCl2, CaCl2, and SrCl2 in HPLC-grade water, respectively. This was done using an ESCA+ system (Omicron NanoTechnology) with a monochromatic Al Kα (1486.7 eV) X-ray source and a hemispherical energy analyzer in ultra-high vacuum. The base pressure of the machine was in the range of 10-10 mbar. The survey spectra were measured with a step size of 0.5 eV, a dwell time of 0.1 s and a pass energy of 100 eV. The take-off angle of the detected photoelectrons was 30° with respect to the surface plane while the source-analyzer angle was 102°. A low energy electron beam (1 eV) was used for neutralization.
Keyword(s):
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)