Loading...
Loading...
Contributors:
Dataset URI:
10.3389/fonc.2026.1968378.s001BackgroundVery small photon fields are sensitive to both measurement conditions and radiation-source modelling, but the connection between effective primary-electron source width, downstream photon angular phase space, and field-size-dependent dosimetric response remains incompletely characterized.MethodsThe study was restricted to 6 MV. Empirical measurement variability was evaluated using five ionization-chamber datasets acquired on a clinical Elekta Versa HD for fields from 20×20 to 3 × 3 cm2. A generalized Versa HD/Agility EGSnrc/BEAMnrc model was evaluated with two prescribed stationary Gaussian source endpoints, M1 (FWHMx = FWHMy = 0.15 cm) and M2 (FWHMx = 0.35 cm, FWHMy = 0.60 cm). DOSXYZnrc dose responses and final pre-phantom photon phase-space data were analysed for 3×3, 2×2, 1×1, and 0.5×0.5 cm2. The 3×3 cm2 field provided the experimental–Monte Carlo overlap; the smaller fields were controlled Monte Carlo endpoint-sensitivity analyses. M1 was additionally benchmarked against a 10×10 cm2 CC13 commissioning PDD.ResultsMean experimental coefficient of variation increased from 2.46% at 20×20 cm2 to 15.45% at 3×3 cm2. The M2 central-axis reductions were 8.48%, 8.27%, 29.59%, and 56.34% for 3×3, 2×2, 1×1, and 0.5×0.5 cm2, respectively. The corresponding M2/M1 ratios of the 95% angular-containment solid angle were 1.275, 1.498, 2.415, and 3.835. The four-field comparison demonstrates clear field-size progression in angular containment, while showing that amplification is observable-dependent rather than universally monotonic. The M1 PDD benchmark supported reference depth-dose behaviour, whereas lateral-profile findings were restricted to controlled numerical sensitivity because absolute lateral agreement was not independently established in this study alone.ConclusionThe demonstrated result is a stationary endpoint-sensitivity chain linking effective primary-electron source representation, linac-head transport, photon angular phase space, and small-field dose/profile response. A reduced covariance formulation is retained only as a prospective framework for testing whether a stationary effective source can represent unresolved accelerator-source states; no time-resolved source dynamics were measured or simulated.
Keyword(s):
angular divergence; BEAMnrc; dynamic source; EGSnrc; Oncology and Carcinogenesis not elsewhere classified.
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)