Loading...
Loading...
Contributors:
Dataset URI:
10.6084/m9.figshare.34886214.v1This repository contains the analysis data and code supporting the study “Walking-only calibration of typical stair electromyography envelopes: incremental value of residual transfer beyond gain calibration”.The study evaluates whether surface electromyography (EMG) recorded during level walking can calibrate predictions of participant-specific typical right-leg EMG envelopes during stair ascent and descent. Five predefined models (M0–M4) are evaluated, with residual transfer (M3) versus gain calibration (M1) as the primary comparison. The analysis uses 120 participants from Gait120, with a fixed split of 80 development participants and 40 internal-test participants, four development folds, five walking calibration cycles in the primary analysis, 20 support-sampling repetitions, and 10,000 participant-level bootstrap resamples. The primary outcome is mean absolute error on a training-reference scale.Package contents include processed EMG envelopes, fixed participant splits, frozen model checkpoints and predictions, participant-level scores, statistical results, numerical figure and table sources, reference figure PDFs, analysis software, implementation tests, a pinned dependency specification, documentation, source attribution, and SHA256 checksums. A numerical excerpt from one original Gait120 walking trial is included to demonstrate the preprocessing procedure.The default reproduction workflow verifies the supplied files, runs the implementation tests and the bundled preprocessing example, rescoring the frozen predictions and reconstructing the statistical summaries and numerical figure and table sources. Validation records document the comparisons and numerical tolerances. This release supports reconstruction from frozen analysis checkpoints. It does not claim complete reprocessing of the original raw cohort or complete retraining and model selection from scratch. No external validation cohort is included.The source dataset is Gait120, available at https://doi.org/10.6084/m9.figshare.27677016.v1, with its associated data descriptor at https://doi.org/10.1038/s41597-025-05391-0. Source attribution and processing changes are documented in the package. This is a secondary analysis of an existing participant resource; it should not be interpreted as a newly recruited cohort or as independent-cohort replication of prior work using the same resource.Licensing: project-authored analysis software and tests are released under the MIT License. The processed analysis data, numerical results, and other analysis materials identified in the package licence map are released under CC BY 4.0. Reused Gait120 material retains its original CC BY 4.0 terms and attribution requirements. Third-party software retains its respective licences. The unpublished manuscript text is not included in this archive and is not covered by these licences.Release version: 1.0.0. Begin with README.md and QUICKSTART_ZH.md. Consult REPRODUCIBILITY_SCOPE.md and validation/VALIDATION.json for the tested reproduction scope and validation evidence.
Keyword(s):
Biomechanics; Biomedical engineering not elsewhere classified; gait Adolescent idiopathic scoliosis.
MeSH Term(s):
Grants and Funding:
No Grants or Funding Data Available
Associated Publication(s):
No Associated Publication Data Available
Supplementary Data:
No Supplementary Data Available
Related Dataset(s):
No Related Dataset Data Available
The National Library of Medicine (NLM) provides information about biomedical datasets. Inclusion on an NLM Web page does not imply endorsement of, or agreement with, the contents by NLM or the National Institutes of Health. Learn more: NLM Web Policies (nih.gov)